Text from PDF Page: 063

Figure 3. 8. 25 cm2 RFB assembly. 3.8- Results and discussions 3.8.1- Investigating the accuracy of the HEAM HEAM needs to prove its accuracy to be utilized for further analysis. Therefore, its accuracy is tested by comparing it to the corrected data from designed experiments and the data from the literature, as illustrated in Figure 3. 9-13. HEAM is sufficiently accurate at predicting pressure drop for RFBs with SFF design (<25% error), however, it is inconsistent to predict the same for RFBs with IFF design (Up to 200% error). This inconsistency roots in the modeling of electrodes, as there are no fitting parameter to relax the error of the model. However, the HEAM accuracy is 44

PDF Image | Analysis of Fluid Flow in Redox Flow Batteries

PDF Search Title:

Analysis of Fluid Flow in Redox Flow Batteries

Original File Name Searched:

Analysis-Fluid-Flow-Redox-Flow-Batteries.pdf

DIY PDF Search: Google It | Yahoo | Bing

Salgenx Redox Flow Battery Technology: Salt water flow battery technology with low cost and great energy density that can be used for power storage and thermal storage. Let us de-risk your production using our license. Our aqueous flow battery is less cost than Tesla Megapack and available faster. Redox flow battery. No membrane needed like with Vanadium, or Bromine. Salgenx flow battery

CONTACT TEL: 608-238-6001 Email: greg@salgenx.com (Standard Web Page)