Section 2.12 Modeling of the hydraulic circuit circular cross-section, the shape factor is 64 [73]. For a Reynolds number beyond 4,000, we assume the flow to be fully turbulent. The friction factor now depends on the Reynolds number and the internal roughness height, [72]. Between a Reynolds number of 2,300 and 4,000, a linear transition region between the laminar and the turbulent behavior is assumed. The Reynolds number is computed as shown in Eq. (2-88) [73]. 64 ReP , fLa fTu fLa ReP 2,300, 2,300 for ReP≤2,300 for 2,300PDF Image | Model-based Design Vanadium Redox Flow Batteries
PDF Search Title:
Model-based Design Vanadium Redox Flow BatteriesOriginal File Name Searched:
10-5445IR1000070670.pdfDIY PDF Search: Google It | Yahoo | Bing
Salgenx Redox Flow Battery Technology: Salt water flow battery technology with low cost and great energy density that can be used for power storage and thermal storage. Let us de-risk your production using our license. Our aqueous flow battery is less cost than Tesla Megapack and available faster. Redox flow battery. No membrane needed like with Vanadium, or Bromine. Salgenx flow battery