Text from PDF Page: 213

RHENIUM Method 264.1 (Atomic Absorption, direct aspiration) STORET NO. Total* OptImum ConcentratIon Range: 50-1000 mgl1 us10g a wavelength of346 Onm SensItIvity: 15 mgl1 DetectIOn LImit: 5 mg/1 PreparatIon of Standard SolutIon 1 Stock solution DIssolve 1 554 g of potassIUm perrhenate, KRe04' In 200 ml deIOmzed water Dlluteto1lIterwIth1%(vIv)H2S04(1ml = 1mgRe) 2 A standard AAS solutIon of ammomum perrhenate, NH4Re04, 1000 mgl1 10 aqueous matnx IS avallable from Alfa Products, Beverly, Massachussetts.01915 Cat #88089 3 Prepare dIlutIOns of the stock solutIOn to be used as calIbratIon standards at the tIme of analysIs The calIbratIOn standards should be prepared us10g 1% (vIv) HN03 Sample PreservatIOn 1 For sample handl10g and preservatIOn, see part 4 1 of the AtomIC AbsorptIon Methods sectIon of thIS manual Sample PreparatIon 1 Transfer a representative 100 ml alIquot of the well mIxed sample to a Gnffin beaker and add 1mlofcone dIstIlledHN03 Placethebeakeronasteambathorhotplateandwarm for 15 mmutes Cool and filter to remove 1Osoluble matenal that could clog the atomIzer Adjustthevolumebackto100ml ThesampleISnowreadyforanalysIs Instrumental Parameters (General) 1 Rhemum hollow cathode lamp 2 Wavelength 3460 nm 3 Fuel Acetylene 4 OXIdant NItrous OXIde 5 Typeofflame Fuelnch AnalysIs Procedure 1 For the analysIs procedure and the calculation, see "dIrect aspIratIOn" part 9.1 of the AtomIC AbsorptIOn Methods sectlOn ofthIS manual *Not AssIgned Issued 1976 Techmcal reVISIon 1978 264 1-1

PDF Image | Methods for Chemical Analysis of Water and Wastes

methods-chemical-analysis-water-and-wastes-213

PDF Search Title:

Methods for Chemical Analysis of Water and Wastes

Original File Name Searched:

epa600_4_79_020.pdf

DIY PDF Search: Google It | Yahoo | Bing

CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info

Heat Pumps CO2 ORC Heat Pump System Platform More Info

CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com | RSS | AMP