logo

Methods for Chemical Analysis of Water and Wastes

PDF Publication Title:

Methods for Chemical Analysis of Water and Wastes ( methods-chemical-analysis-water-and-wastes )

Previous Page View | Next Page View | Return to Search List

Text from PDF Page: 376

6 II, Stock mtrate solutIOn DIssolve 7 218 g KN03 and dIlute to 1 lIter m a volumetnc flask wIth dIstilled water Preserve wIth 2 ml of chloroform per lIter SolutIon IS stable for 6 months 1ml= 10mgN03-N 6 12 Stock mtnte SolutIon DIssolve 6 072 g KN02 m 500 ml ofdIstilled water and dIlute to 1 lIter m a volumetnc flask Preserve wIth 2 ml ofchloroform and keep under refngeratIOn 1OmI =10mgN02-N 6 13 Standard mtrate SolutIon DIlute 10 0 ml ofstock mtrate solutIOn (6 11) to 1000 ml 10 ml = 001 mg NOrN Preserve wIth 2 ml ofchloroform per hter SolutIOn IS stable for 6 months 6 14 Standard mtnte SolutIon DIlute 100 ml ofstock mtnte (6 12) solution to 1000 ml 10m! = 001mgN02-N SolutIOnISunstable,prepareasreqUIred 6 15 Usmg standard mtrate SolutIon (6 13), prepare the followmg standards m 1000 ml volumetnc flasks At least one mtnte standard should be compared to a mtrate standard at the same concentratIon to venfy the effiCIency of the reductIOn column ml Standard SolutIOnllOO ml 00 o 005 05 010 10 020 20 050 50 100 100 200 200 400 400 600 600 NOTE 2' When the samples to be analyzed are salIne waters, Substitute Ocean Water (SOW).should be used for prepanng the standards, otherWIse, dIstilled water IS used A tabulatIOn ofSOW compOSItion follows NaCI- 2453gil CaCl2 - 116 gil KBr - 010 gil NaF- 0003gil 7 Procedure MgCl2 - 520gil KCI - 070 gil H3B03 - 003 gil Na2S04 - 409gil NaHC03 - 020 gil SrCl2 - 003 gil 7 1 72 73 If the pH of the sample IS below 5 or above 9, adjust to between 5 and 9 WIth eIther conc HClorconc NH40H Set up the mamfold as shown m FIgure 2 (AAI) or FIgure 3 (AAII) Note that reductant 0 column should be m 20 mclme pOSItIOn (AAI) Care should be taken not to mtroduce aIr mto reductIOn column on the A A II Allow both colonmeter and recorder to warm up for 30 mmutes Obtam a stable baselIne WIth all reagents, feedmg dIstilled water through the sample lme NOTE 3: CondItIon column by runnmg 1 mgll standard for 10 mmutes If a new reductIon column IS bemg used Subsequently wash the column WIth reagents for 20 mmutes 3532-4

PDF Image | Methods for Chemical Analysis of Water and Wastes

methods-chemical-analysis-water-and-wastes-376

PDF Search Title:

Methods for Chemical Analysis of Water and Wastes

Original File Name Searched:

epa600_4_79_020.pdf

DIY PDF Search: Google It | Yahoo | Bing

CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info

Heat Pumps CO2 ORC Heat Pump System Platform More Info

CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com | RSS | AMP