CHAPTER 5: ECONOMICAL COMPARlSON BETWEEN ILH, R-22 AND CO2 SYSTEM 125 already be costing its owner more than the two heat pump systems would because of its high operating cost. For the two heat pumps it is clear that the higher capital cost of the CO2 machine makes it a more expensive option when considering the two systems. The CO2 heat pump system will cost the consumer more initially than it would cost to install the R-22 system. However, it can be seen that after a period of four years the CO2 system will be the less expensive option because of its lower operating cost A Teclmo-Economica1 Analysis ofa CO2 Heat Pump. School of Mechanical Engineering, North-West University

PDF Image | CO2 HEAT PUMP Analysis

PDF Search Title:

CO2 HEAT PUMP Analysis

Original File Name Searched:

co2-heat-pump-techno-analysis.pdf

DIY PDF Search: Google It | Yahoo | Bing

CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info