logo

CO2 Heat Pumps Revere 28

PDF Publication Title:

CO2 Heat Pumps Revere 28 ( co2-heat-pumps-revere-28 )

Previous Page View | Next Page View | Return to Search List

Text from PDF Page: 005

Revere® CO2 - Air to Water Heat Pumps CHP-5R CHP-15HF CHP-26H4 CHP-080Y2 General Performance Data of a Standard Unit Product Code Power supply Total power input@ 25oC ambient(kW) Heating output @ 25oC ambient (kW) Average COP* Dimension L x W x H(mm) CHP-5R** CHP-15F CHP-26H4 CHP-080Y2 Single phase 240V/50Hz 3 phase 415V/50Hz 3 phase 415V/50Hz 3 phase 415V/50Hz 2.3 5.5 3.9 4.16 15 4.0 6.7 29.3 3.9 18.8 78.4 3.8 675 x 825 (+70) x 300 900 x 450 x 1850 1300 x 890 x 1705 1790 x 1010 x 2000 * Average COP based on constant hot water supply at 65oC and ambient temperature range of -7oC to 43oC. ** Hot water temperature for model CHP-5R is fixed at 63°C. CO2 heat pump system for DHW and space heating on skid frame. 5

PDF Image | CO2 Heat Pumps Revere 28

co2-heat-pumps-revere-28-005

PDF Search Title:

CO2 Heat Pumps Revere 28

Original File Name Searched:

Revere-CO2-Heat-Pump-brochure_v2.8.pdf

DIY PDF Search: Google It | Yahoo | Bing

CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info

Heat Pumps CO2 ORC Heat Pump System Platform More Info

CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com | RSS | AMP