Revere® CO2 - Air to Water Heat Pumps CHP-5R CHP-15HF CHP-26H4 CHP-080Y2 General Performance Data of a Standard Unit Product Code Power supply Total power input@ 25oC ambient(kW) Heating output @ 25oC ambient (kW) Average COP* Dimension L x W x H(mm) CHP-5R** CHP-15F CHP-26H4 CHP-080Y2 Single phase 240V/50Hz 3 phase 415V/50Hz 3 phase 415V/50Hz 3 phase 415V/50Hz 2.3 5.5 3.9 4.16 15 4.0 6.7 29.3 3.9 18.8 78.4 3.8 675 x 825 (+70) x 300 900 x 450 x 1850 1300 x 890 x 1705 1790 x 1010 x 2000 * Average COP based on constant hot water supply at 65oC and ambient temperature range of -7oC to 43oC. ** Hot water temperature for model CHP-5R is fixed at 63°C. CO2 heat pump system for DHW and space heating on skid frame. 5PDF Image | CO2 Heat Pumps Revere 28
PDF Search Title:
CO2 Heat Pumps Revere 28Original File Name Searched:
Revere-CO2-Heat-Pump-brochure_v2.8.pdfDIY PDF Search: Google It | Yahoo | Bing
CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info