PDF Publication Title:
Text from PDF Page: 020
DESCRIPTION OF TESTING PROCEDURES The testing work is performed at different outdoor temperatures and in four different stages: Stage 1. The heat pump unit is tested without the influence of water tank. The performance is tested by maintaining the water inlet temperature to the heat pump constant, while recording all the other data. The tested performance is then compared with the performance data provided by the manufacturer in the technical manual. Stage 2. The heat pump is tested together with the water tank and the radiator load (i.e. system testing). A plate heat exchanger cooled by city water is connected to the water tank to simulate the radiator system. Different cooling water flow rates are used to simulate different house heating demands. The COP of the system is recorded. Stage 3. The defrosting scheme of the heat pump is studied. Stage 4. The water temperature distribution in the tank is recorded. The tank performance at different conditions is studied. 19PDF Image | CO2 heat pumps for the Swedish market
PDF Search Title:
CO2 heat pumps for the Swedish marketOriginal File Name Searched:
P3-slutrapport.pdfDIY PDF Search: Google It | Yahoo | Bing
CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info
Heat Pumps CO2 ORC Heat Pump System Platform More Info
CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com | RSS | AMP |