Text from PDF Page: 008
HPWH Performance Report set-points of 130°F (54.4°C) except Kelowna Site 4 which was reset at 135°F (57.2°C) at the occupant’s request. ➢ All Rheem units were set to the factory-default Energy Saver mode which optimizes heat pump and electric resistance heat for low power consumption and high recovery. See Appendix for description of the other operating modes (Heat Pump, High Demand, Electric, and Vacation). 6PDF Image | CO2 Integrated Heat Pump Water Heater
PDF Search Title:
CO2 Integrated Heat Pump Water HeaterOriginal File Name Searched:
CO2-Integrated-Heat-Pump-perf.pdfDIY PDF Search: Google It | Yahoo | Bing
CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info