Text from PDF Page: 049

HPWH Performance Report 10.4 Kelowna Site 1 (Sanden) Observed data: Kelowna Site 1 is equipped with a 160-litre (43-gallon) tank and this Winter report includes 134-days of metered data. The unit has performed with a COP of 1.56 over a period with an average ambient temperature of -1.5°C [29°F] and an average water draw of 73 litres per day (19.4 gallons per day). Site Unit Type Tank Size Beginning Date Ending Date Days of Monitoring Period Kelowna Site 1 Table 28: Kelowna Site 1 Summary Sanden 160-L [43-gal] 11/8/16 2/16/18 447 Table 29: Kelowna Site 1 Variables Site COP Average Ambient Temp Average Water Flow Average Hot Water Temp Average Inlet Water Temp 6.6°C 74 LPD 52.4°C Kelowna Site 1 1.86 [44°F] [20 GPD] [126°F] Figure 36: Kelowna Site 1 Monthly COP 16.5°C [61.7°F] 3 30 2.61 2.30 25 20 15 10 5 0 -5 -10 2 1 1.52 1.62 February 1.96 2.11 March April 2.00 2.00 July August Average Air Temperature 1.77 1.85 September October 1.68 November 1.50 December 0 January May COP June 38 COP Ambient Air Temperature (°C)

PDF Image | CO2 Integrated Heat Pump Water Heater

PDF Search Title:

CO2 Integrated Heat Pump Water Heater

Original File Name Searched:

CO2-Integrated-Heat-Pump-perf.pdf

DIY PDF Search: Google It | Yahoo | Bing

CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info

Heat Pumps CO2 ORC Heat Pump System Platform More Info

CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com (Standard Web Page)