PDF Publication Title:
Text from PDF Page: 077
HPWH Performance Report 11.5 Vancouver Island Site 5 (Rheem) Observed data: The Vancouver Island Site 5 unit is a 246-litre (65-gallon) Rheem water heater that has performed with a COP of 2.06 over a 363-day period with an average garage temperature of 16.7°C (62°F) and 279 litres per day (74 gallons per day) of average water draw. This unit was installed in the garage and saw slightly warmer ambient temperatures and better annual performance than the other Vancouver Island sites. Site Unit Type Tank Size Beginning Date Ending Date Days of Monitoring Period V. Island Site 5 V. Island Site 5 Table 49: Vancouver Island Site 5 Summary 246-L Rheem [65-gal] 2/17/17 2/15/18 Table 50: Vancouver Island Site 5 Variables 16.7°C31 279 LPD 49.7°C 2.06 [62°F] [74 GPD] [121°F] 363 13.5°C [56°F] Site aCOP Average Garage Air Temp Average Water Flow Average Hot Water Temp Average Inlet Water Temp Figure 59: Vancouver Island Site 5 Monthly Performance 4 3 2 1.84 1.73 1 3.08 2.51 2.77 25 20 15 10 5 2.21 2.41 2.25 1.80 1.86 1.93 1.95 00 January February March April May June July August September October November December COP Average Air Temperature 31 The Vancouver Island Site 5 unit is unducted and uses garage air as the heat source until outdoor air starts replacing the garage air after extended heat pump operation. 66 COP Ambient Air Temperature (°C)PDF Image | CO2 Integrated Heat Pump Water Heater
PDF Search Title:
CO2 Integrated Heat Pump Water HeaterOriginal File Name Searched:
CO2-Integrated-Heat-Pump-perf.pdfDIY PDF Search: Google It | Yahoo | Bing
CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info
Heat Pumps CO2 ORC Heat Pump System Platform More Info
CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com (Standard Web Page)