comparison and reconfigured to eliminate the gas-vapor line flooding. All of the following results are for the ARI 21oC/8.3oC indoor/outdoor heat pump rating condition. B.2 Experimental Results Figure B.2 shows a comparison of the capacity and heating COP of the R744 system for the R744/R410A comparison and the vertical indoor coil with the suction accumulator adjusted and unadjusted. The capacity shown in Figure B.2 is based on the indoor chamber energy balance, which is believed to be the most accurate balance (during the experiments with the vertical coil runs the glycol energy balance agreed with the electrical input to the chamber within 1.5%). The capacity of the re-orientated coil/no suction accumulator adjustment is about 5% higher than the other two cases, while the efficiency of both the re-orientated cases is between 5 and 10% higher than the R744/R410A comparison results. From Figure B.3, which shows the compressor work for each of the points plotted in Figure B.2, it is evident that higher efficiency for the re-orientated coil/no suction accumulator adjustment is primarily from the increased capacity. The improvement for the re-orientated/suction accumulator adjusted case is primarily the result of a decrease in the compressor power. 10.6 10.4 10.2 10.0 9.8 9.6 9.4 9.2 9.0 7400 7600 7800 8000 8200 8400 Discharge Pressure (kPa) 4.3 4.2 4.1 4.0 3.9 3.8 7400 7600 7800 8000 8200 8400 Discharge Pressure (kPa) Comparison with R410A results Re-orientated indoor coil/No suct. acc. adjust. Re-orientated indoor coil/Suct. acc. adjust. Figure B.2 Comparison of capacity and efficiency with re-orientation of indoor coil and adjustment of suction accumulator 60 Capacity (kW) Heating COP

PDF Image | Comparison of R744 and R410A

comparison-r744-and-r410a-071

PDF Search Title:

Comparison of R744 and R410A

Original File Name Searched:

CR039.pdf

DIY PDF Search: Google It | Yahoo | Bing

CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info

Heat Pumps CO2 ORC Heat Pump System Platform More Info

CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com | RSS | AMP