7.4.2 Fix trunking Figure 7.21 Install trunking neatly • Screw-fix proprietary trunking to the exterior wall from the outlet to the outdoor unit. • Use stainless steel screws. • Install trunking neatly in straight runs with 90o angles, tight weather seals and waterproof flashings (Figure 7.21). • Run horizontal trunking with a slight downhill slope if it contains the condensate drainage pipe. • Fit refrigerant piping, drainage pipe and connecting cable into trunking (Figure 7.22). • Attach trunking cover. • Fill hole around piping with sealant compatible with the trunking and the cladding system (Figure 7.23). • Seal around and fit cover over opening (Figures 7.24 and 7.25). Figure 7.22 Fit refrigerant piping, drainage pipe and connecting cable into trunking Figure 7.23 Fill hole around piping with sealant Figure 7.24 Seal around cover Figure 7.25 Fit cover over opening Do not use trunking indoors. 41

PDF Image | Heat pump installation Good Practice Guide

heat-pump-installation-good-practice-guide-041

PDF Search Title:

Heat pump installation Good Practice Guide

Original File Name Searched:

Good_practice_heat_pump_installation.pdf

DIY PDF Search: Google It | Yahoo | Bing

CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info

Heat Pumps CO2 ORC Heat Pump System Platform More Info

CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com | RSS | AMP