PDF Publication Title:
Text from PDF Page: 057
12.1 Case 1 – Auckland 12.1.1 Step 1: Determine requirements Heating/cooling requirements ❏❏ Primarily for heating. ❏❏ Auckland region, open site. ❏❏ New home. ❏❏ Family room is to be heated by the heat pump. Checklist of building conditions ❏❏ North facing. ❏❏ Good solar access. ❏❏ Areas of windows, floors and external walls calculated for the space. ❏❏ Complies with current Building Code (2008 onwards) – high levels of insulation and double glazing. 12.1.2 Steps 2 and 3: Determine design temperature and heat load requirement 57PDF Image | Heat pump installation Good Practice Guide
PDF Search Title:
Heat pump installation Good Practice GuideOriginal File Name Searched:
Good_practice_heat_pump_installation.pdfDIY PDF Search: Google It | Yahoo | Bing
CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info
Heat Pumps CO2 ORC Heat Pump System Platform More Info
CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com | RSS | AMP |