12.3 Case 3 – Dunedin 12.3.1 Step 1: Determine requirements Heating/cooling requirements • Primarily for heating. • Already have a wood burner that they are keeping and will use during the colder parts of winter in the family room – see location on plan at B. • Dunedin, sloping site with good solar access. • New home. • Family room is to be heated by the heat pump. Checklist of building conditions • Good solar access to the family room. • Areas of windows, floors and external walls calculated for the space. • Complies with current Building Code (2008 onwards) – high levels of insulation and double glazing. 12.3.2 Steps 2 and 3: Determine design temperature and heat load requirement 61PDF Image | Heat pump installation Good Practice Guide
PDF Search Title:
Heat pump installation Good Practice GuideOriginal File Name Searched:
Good_practice_heat_pump_installation.pdfDIY PDF Search: Google It | Yahoo | Bing
CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info