Heat Pump Systems 2020

PDF Publication Title:

Heat Pump Systems 2020 ( heat-pump-systems-2020 )

Previous Page View | Next Page View | Return to Search List

Text from PDF Page: 049

Figure 6-6 7/16" oriented strand board batt insulation 3/4" foil faced foam insulation 1/2" PEX-AL-PEX tubing, 8" spacing 6" aluminum heat transfer plates, 8" spacing 1/2" drywall q=0.71×(Twa −Troom) Thus, if the radiant wall panel operates with an average water temperature of 110oF in a room with 70oF air temperature, each square foot of heated wall would release about 0.8 x (110 - 70) = 32 Btu/hr/ft2. RADIANT CEILING PANELS Another possibility is a radiant ceiling panel using the same materials and construction methods as the radiant wall panel. Figure 6-6 shows a cross section of this construction. Figure 6-7 shows an example of a radiant ceiling under construction. In this construction, the 1/2” PEX-AL-PEX tubes are spaced 8 inches apart. The plates are 5 inches wide. The Figure 6-7 life of the building. They are also ideal surfaces for radiant cooling using chilled water supplied from an air-to-water heat pump. However, when radiant cooling is 3/4-inch foil-faced polyisocyanurate foam insulation strips q=k(Twa −Troom)=15=k(115−70) are “held back” near the U-bends in the tubing. A 3/4- inch thick furring board runs adjace1n5t to the upper plate of k = = 0.333 the partition. This assembly will be covered with 1/2-inch 115−70 drywall. 2.5-inch long drywall screws will be installed halfway between adjacent tubes and spaced 12 inches apart in the direction parallel with the tubes. q=0.8×(T −T ) The rate of heat emission to the room can be estimated using Formula 6-3: Formula 6-3: where: q = heat output of ceiling panel (Btu/hr/ ft2) T = averat(gQe water−teqmpe)rature in wa V = heat source load panel (oF) Troom = room air temperature (oF) 500(ΔT) Heated ceilings have the advantage wa room of not beingt Qcovered −oqr block1e0d 4b8y000 − 2000 ()() V = heat source load coverings or furniture, and thus, are likely = 500(ΔT) 500(120−100) to retain good performance over the used, it is critical to maintain the chilled water temperature above the dewpoint COPave = ( ) of the interior air. kwhr used × 3413 More information on radiant cooling is available in idronics #13. PANEL RADIATORS Generously sized panel radiators can also provide good performance when used as part of a hydronic heat pump system. The suggested guideline is to Btu delivered 49

PDF Image | Heat Pump Systems 2020

PDF Search Title:

Heat Pump Systems 2020

Original File Name Searched:

idronics_27_na.pdf

DIY PDF Search: Google It | Yahoo | Bing

CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info

Heat Pumps CO2 ORC Heat Pump System Platform More Info

CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com (Standard Web Page)