PDF Publication Title:
Text from PDF Page: 050
Table 1 Comparative results from previous experimental studies Gas cooler & evaporator configuration Operating conditions (Water temperatures ) for tap water heating Space heating conditions Evaporation temperature Nominal heating capacity COP Year Peter Nekså (One Hex as gas cooler) Coaxial HExs 8-60 oC 0 oC 50 kW 4.2 1998 Jørn stene (3 Hexs as gas cooler) Counter flow, tube in tube HExs 6.5-60/70/80 oC 33/28, 35/30, 40/35 oC -5 oC 6.5 kW 3.9 for 60 oC and 80% DHW capacity ratio 2005 Fornasieri (One heat exchanger) Double wall plate Hex 14.7 to 60.2 oC 1.8 oC 20 kW 3.8 2010 KTH (2 HExs in series) Plate HExs 15-60 oC 0 oC 30 kW 3.8/4.3a 2010 a. COP from direct reading/COP from indirect reading With the heat pump facility at energy department of KTH, on average optimum COP value of about 4 was achievable. So, it can be concluded that the system performance is quite comparable with other quoted results. 38PDF Image | heat recovery from R744 based refrigeration system
PDF Search Title:
heat recovery from R744 based refrigeration systemOriginal File Name Searched:
r744-heat-recovery.pdfDIY PDF Search: Google It | Yahoo | Bing
CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info
Heat Pumps CO2 ORC Heat Pump System Platform More Info
CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com (Standard Web Page)