MHP Specifications TECHNICAL SPECIFICATIONS: MHP Air-Cooled Heat Pumps MHP 1200 1500 2200 3000 3500 4000 5000 6000 7200 with SCROLL compressors (15-50 tons) NOMINAL COOLING CAPACITY EWT 54°F LWT 44°F AMB 95° Nominal Power Cooling Mode NOMINAL HEATING CAPACITY EWT 104°F LWT 114°F AMB 45°F Nominal Power Heating Mode REFRIGERATING CIRCUIT SCROLL COMPRESSOR CAPACITY STEPS FANS / CONDENSER FANS / CONDENSER MHP FANS OPTIONAL PUMP & TANK NOMINAL FLOW NOMINAL EVAPORATOR PRESSURE DROP NOMINAL PUMP PRESSURE NOMINAL PUMP ABSORBED POWER OPTIONAL PUMP ABSORBED CURRENT VICTAULIC CHILLED WATER CONNECTIONS OPTIONAL TANK VOLUME MHP SOUND PRESSURE LEVEL** MHP LOW NOISE SOUND PRESSURE LEVEL** DIMENSIONS AND WEIGHTS MHP Length MHP Width MHP Height BTU/h kW BTU/H kW Qty. 173,436 194,000 19 24 187,000 211,000 20 24 1 1 221,000 245,000 25 30 245,000 271,000 26 30 1 1 2 2 296,000 344,000 385,000 34 40 46 330,000 375,000 429,000 33.25 40 75 1 1 1 2 3 2 453,000 522,000 57 65 513,000 595,000 55 63 1 2 2 2 Qty. 2 2 Qty. 2 2 2 2 2 3 2 2 2 CFM 11,000 11,000 11,000 11,000 11,000 15,000 15,000 20,000 20,000 Qty. 2 2 2 2 2 2 2 3 3 GPM 34 39 PSI 5 6 PSI 15 13 HP 1 1 A 3 3 IN 1.5” 1.5” gallons 50 50 dbA 69 69 dbA 66 66 IN 100.5 100.5 IN 47.3 47.3 45 50 5 7 13 11 1 1 3 3 1.5” 1.5” 50 50 70 70 67 67 100.5 100.5 47.3 47.3 60 69 77 5 6 9 16 13 12 1.5 1.5 1.5 3.5 3.5 3.5 1.5” 2.5” 2.5” 50 75 75 70 73 74 67 71 71 100.5 100.5 100.5 47.3 47.3 47.3 91 104 8 7 12 15 2 2 5 7 2.5” 2.5” 125 125 74 74 71 73 140 140 47.3 47.3 IN 89 89 89 89 89 89 89 89 89 MHP Weight - Installed* LBS 1,387 1,474 1,518 1,760 1,958 2,068 2,310 2,530 3,058 MHP Air-Cooled Heat Pumps with SCROLL compressors (60-240 tons) MHP 200 240 270 390 430 470 510 600 660 700 820 930 NOMINAL COOLING CAPACITY EWT 54°F LWT 44°F AMB 95°F Nominal Power Cooling Mode NOMINAL HEATING CAPACITY EWT 104°F LWT 114°F AMB 45°F Nominal Power Heating Mode REFRIGERATING CIRCUIT SCROLL COMPRESSOR CAPACITY STEPS FANS / CONDENSER MHP TOTAL CONDENSER AIR FLOW MHP FANS NOMINAL FLOW NOMINAL EVAPORATOR PRESSURE DROP NOMINAL PUMP PRESSURE NOMINAL PUMP ABSORBED POWER OPTIONAL PUMP ABSORBED CURRENT VICTAULIC CHILLED WATER CONNECTIONS*** MHP FULL LOAD AMPS (FLA)* MHP SOUND PRESSURE LEVEL** MHP LOW NOISE SOUND PRESSURE LEVEL** MHP Length BTU/h 696,000 825,000 911,000 1,328,124 1,395,000 1,560,000 1,729,000 2,000,000 2,258,000 2,415,000 2,627,000 2,869,000 kW 78 98 104.5 145 160 175 215 230 272 277 320 367 BTU/h 750,000 931,000 1,023,000 1,355,000 1,560,000 1,770,000 1,980,000 2,240,000 2,531,000 2,808,000 3,104,000 3,412,000 kW 88 107 114 153 198 216 231 269 348 273 312 350 Qty. 2 2 2 2 2 2 2 2 2 4 4 4 Qty. 4 4 4 4 4 4 6 6 6 8 8 8 Qty. 4 4 4 4 4 4 6 6 6 8 8 8 CFM 45,961 61,000 61,000 61,000 82,000 82,000 82,000 120,000 120,000 130,000 130,000 140,000 Qty. 4 6 6 6 8 8 8 10 10 12 12 14 OPTIONAL PUMP SYSTEM GPM 137 168 185 238 280 310 335 396 457.9 PSI 7 6 6 8 8 9 10 9 10 PSI 19 15 14 18 HP 4 4 4 7.5 A 6.5 6.5 6.5 13 17 15 7.5 7.5 13 13 483 524 572 11 13 15 18 16 14 15 15 15 25 25 25 6 6 6 354 457 525 80 82 84 86 89 91 78 79 84 83 86 88 240 284 284 376 376 376 IN 3” 3” 3” 3” 3” 3” 20 17 17 10 10 10 18 18 18 3” 3” 6” A 133 171 174 220 dbA 76 76 79 79 dbA 74 74 77 77 IN 110 158 158 158 279 336 81 83 78 79 197 197 576 645 722 NOISE DATA DIMENSIONS AND WEIGHTS Does not include optional pump(s) ** Optional Pumps & Tank may effect dimensions *** Does not include Optional pump(s) or tank (1) Series heat recovery configuration. Pumps and tank not available on MHR-W © 2020 Motivair Corporation. Motivair reserves the right to modify specifications without notice. Reproduction of this brochure in whole or in part is prohibited. OUR BUSINESS IS COOLING YOURSTM motivaircorp.com

PDF Image | MHP Air Source Heat Pump

PDF Search Title:

MHP Air Source Heat Pump

Original File Name Searched:

MHP Air Source 2021.pdf

DIY PDF Search: Google It | Yahoo | Bing

CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info

Heat Pumps CO2 ORC Heat Pump System Platform More Info

CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com (Standard Web Page)