QAHV-N560YA-HPB

PDF Publication Title:

QAHV-N560YA-HPB ( qahv-n560ya-hpb )

Previous Page View | Next Page View | Return to Search List

Text from PDF Page: 018

3 Configuration method and selection criteria of flow rate adjustment device In this system, a flow rate adjustment device is installed in the secondary side circuit to perform secondary side flow rate adjustment control by outputting 0 to 10 V from the unit. * 10-V power supply is not supplied. The following shows a system configuration example of the flow rate adjustment device and notes on the system configuration. The following three system types are recommended as flow rate adjustment devices: 1. System using a three-way valve 2. System using a two-way valve 3. System using an inverter 1. System using a three-way valve Notes on selection method and system configuration Notes on pump selection and connection Overview of system This system has a pump provided at the outlet of the tank and a three-way valve provided downstream of the pump, and adjusts the flow rate by controlling the opening and closing of the three-way valve. Wiring connection places ON/OFF signal 0 to 10 V output Three-way Pump valve Flow rate output device Flow rate adjustment device Pump Three-way valve 1-3 of CN512 of control board (ON/OFF output) Sub box terminal block No. 10, 11, 12 • Calculate the total pump head according to the system at the site and then select a pump capable of outputting the minimum flow rate of about 3 l/min and maximum flow rate of about 30 l/min with the necessary pump head for the piping at the site. • When selecting the pump, please note that output at a high flow rate will not occur if the flow rate with the pump head of the system at the site is low, and output at a low flow rate will not occur if the flow rate is too high. • Be sure to check that the flow rate becomes 20 to 30 l/min at the maximum output during a flow rate adjustment test run (refer to page 37). For how to check the flow rate, refer to page 38. * If the flow rate is not within the range of 20 to 30 l/min, select a different pump or adjust the maximum frequency using an inverter, etc. so that the maximum flow rate of 20 to 30 l/min is achieved. * To select a proper pump, first select a pump that supports slightly high flow rate, and then adjust the frequency with an inverter so that the flow rate becomes 20 to 30 l/min at the maximum output. (In that case, an inverter is necessary to be prepared separately.) Notes on three-way valve selection and connection • Use a valve that is capable of adjusting the flow rate with a 0 to 10 V input. • Calculate the Cv value and select a valve that supports an appropriate rate. • Select a valve of which the ratio of the maximum flow rate and the minimum flow rate will be at least 1:10. • Place the three-way valve downstream of the pump. Connect one outlet to the heat exchanger. Connect the other outlet to the lower part of the tank. • Carefully read the instruction manual and use the three-way valve in accordance with the usage procedures. 18

PDF Image | QAHV-N560YA-HPB

PDF Search Title:

QAHV-N560YA-HPB

Original File Name Searched:

IBIM_WT08219X05_QAHV_N560YA_HPB_ML.pdf

DIY PDF Search: Google It | Yahoo | Bing

CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info

Heat Pumps CO2 ORC Heat Pump System Platform More Info

CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com (Standard Web Page)