(6) Setting the total number of units for a multiple system Set SWS1 to OFF from the remote controller or with the local switch. Settings cannot be changed unless the ON/OFF switch is set to OFF. Set the dip switches on the circuit board as follows to select how external inputs are received. SW2 SW3 -10 5 6 7 8 9 10 OFF OFF OFF OFF ON ON ON The item codes shown in the table below will appear in order every time the push switch SWP3 is pressed. Use the push switches SWP1 and SWP2 to change the value of the selected item. The value will keep blinking while it is being changed. Setting table *1 Enter the total number of units including the main unit. Applicable only to the main unit. *2 0: Sub unit 1: Main sensor 2: Sub sensor (For six-sensor method) *3 Set the address of the sub sensor for six-sensor method. *4 0: Secondary side control disabled 1: Secondary side control enabled Press SWP3 once within one minute of changing the setting with SWP1 or SWP2 to save the setting. Once the new setting is saved, the display will stop blinking and stay lit. The display will, then, return to the item code display mode. If SWP3 is not pressed within one minute, the change will not be saved and the display will return to the item code display mode. After changing the settings, re-initialize the system according to the procedures detailed on page 32. Note The new setting will not be saved unless a reset is performed. Setting the unit addresses Refer to “(4) System configuration procedures : Multiple system” (page 29). Step 0 Set the ON/OFF switch (SWS1) to OFF. Step 1 Set the dip switches SW2 and SW3. Step 2 Select the desired item with the push switch SWP3. Step 3 Press the push switches SWP1 (↑) or SWP2 (↓) to increase or decrease the value. Unit address Total number of units in the system*1 AE-200 connection Own unit role*2 Main sensor address Sub sensor address*3 Secondary circuit control*4 Item code 105 106 107 110 111 112 121 Increments 1 1 2 1 1 1 1 Lower limit 1 0 0 0 1 1 0 Upper limit 8 16 2 2 50 51 1 Initial value 2 1 0 0 1 51 0 Step 4 Press the push switch SWP3 to save the change. Step 5 Turn the power back on. Reset the system. 49

PDF Image | QAHV-N560YA-HPB

qahv-n560ya-hpb-049

PDF Search Title:

QAHV-N560YA-HPB

Original File Name Searched:

IBIM_WT08219X05_QAHV_N560YA_HPB_ML.pdf

DIY PDF Search: Google It | Yahoo | Bing

CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info

Heat Pumps CO2 ORC Heat Pump System Platform More Info

CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com | RSS | AMP