QAHV-N560YA-HPB

PDF Publication Title:

QAHV-N560YA-HPB ( qahv-n560ya-hpb )

Previous Page View | Next Page View | Return to Search List

Text from PDF Page: 057

57 1. The broken lines indicate the optional parts,field-supplied parts,and field work. Symbol explanation Note 2. Dashed lines indicate sub box CT12 CT22 Ac current sensor 3. Faston terminals have a locking function. CT3 Press the tab in the middle of the terminals to remove them. C100 Capacitor (Electrolysis) DCL DC reactor F01 F02 Check that the terminals are securely locked in place after insertion. 4. The symbols of the field connecting terminals are as follows. :Terminal block :Connection by cutting the short circuit wire F03 5. The method of input signal of operation can choose one of optinal remote controller or no-voltage input. F04 Fuse F06 F07 6. Leave a space of at least 5 cm between the low voltage external wiring F121 (no-voltage contact input and remote controller wiring) and wiring of 100V or greater.Do not place them in the same conduit tube or cabtyre cable as this will damage the circuit board. H1 Crankcase heater (for heating the compressor) H2 Electric heater (Antifreeze) LEV1 Electronic expansion valve (Main circuit) LEV3 Electronic expansion valve (Injection) 7. When cabtyre cable is used for the control cable wiring, use a separate cabtyre cable for the following wiring. Using the same cabtyre cable may cause malfunctions and damage to the unit. M Fan motor MP1 Pump motor MS Compressor motor MVW1 Water flow control valve PSH1 High pressure sensor PSL1 Low pressure sensor R11 Resistance (for Water flow rate sensor 2) R12 Resistance (for Water flow rate sensor 3) (a) Optional remote controller wiring (b) No-voltage contact input wiring (c) No-voltage contact output wiring (d) Remote water temperature setting R1 Electrical resistance R5 8. Use a contact that takes 12VDC 1mA for no-voltage contact input. 9. Need to selects either Water temperature setting input signal. SV1 Solenoid valve (Defrost)1 SV2 Solenoid valve (Defrost)2 SV3 Solenoid valve (Defrost)3 SV4 Solenoid valve (Defrost)4 SV5 Solenoid valve (Injection circuit) S1 Water flow rate sensor Set the SW421 as shown in the table below. SW421-1 SW421-2 4~20mA ON ON THHS IGBT temperature TH1~5,9,11,12,14 Thermistor Z21 Function setting connector 63H1 High pressure switch 72C Electromagnetic relay (Inverter main circuit) *TH15~18 Thermistor *S2,3 Water flow rate sensor 0~10V 1~ 5V 2~10V OFF OFF OFF ON OFF OFF 10.Use a 4-20mA signal output device with insulation. Feeding 30mA or more current may damage the circuit board. Earth leakage breaker * of symbol item is the optional parts, <> is field-supplied parts. 11.For prevention of damage of the pump, SWS2 is set in "A"(factory setting). Change the slide switch SWS2「B(automatic)」in Test Run. 12.Use a contact that takes 250VAC, 10mA or above, and 1A or below for no-voltage contact output. Symbol explanation

PDF Image | QAHV-N560YA-HPB

PDF Search Title:

QAHV-N560YA-HPB

Original File Name Searched:

IBIM_WT08219X05_QAHV_N560YA_HPB_ML.pdf

DIY PDF Search: Google It | Yahoo | Bing

CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info

Heat Pumps CO2 ORC Heat Pump System Platform More Info

CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com (Standard Web Page)