Reclaim CO2 Hot Water Heat Pump Design

PDF Publication Title:

Reclaim CO2 Hot Water Heat Pump Design ( reclaim-co2-hot-water-heat-pump-design )

Previous Page View | Next Page View | Return to Search List

Text from PDF Page: 005

Reclaim CO2 heat pump specification EHPE-4540P 0.916 kW 4.7 kW 5.24 R744 (CO2) 63°C 240 V / 50 Hz 10.0 Amps 2.3 kW 37 dB -10°C to 43°C 675 x 922 x 300mm 48 kg IP4 1⁄2” BSP / 12.7mm * Test conditions 19°C ambient air temperature, 15°C cold water temperature- AS/NZS 5125:2014 Hot water heat pumps Model number Power input* Thermal output* COP* Refrigerant Output water temperature Power supply Current input (max) Power input (max) Noise level at 1m Ambient temperature Dimensions (H x W x D) Weight Rain resistance Water port connections (inlet/outlet)

PDF Image | Reclaim CO2 Hot Water Heat Pump Design

PDF Search Title:

Reclaim CO2 Hot Water Heat Pump Design

Original File Name Searched:

Reclaim-CO2-HWHP-design-guide-v2.pdf

DIY PDF Search: Google It | Yahoo | Bing

CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info