PDF Publication Title:
Text from PDF Page: 007
Install details and seismic restraint for Reclaim 300L cylinders The cylinder must be installed according to all requirements of G12 AS2:2017, specifically: - If installed indoors the cylinder must be placed in an appropriately sized safe tray with adequate drainage to outside the building envelope, as per G12 5.2.3 - All pipework connections and valves must be accessible for inspection, maintenance and removal, as per G12 6.11.2 - Structural support and seismic restraint must be fitted for the cylinder, as illustrated below and as per G12 6.11.4PDF Image | Reclaim CO2 Hot Water Heat Pump Design
PDF Search Title:
Reclaim CO2 Hot Water Heat Pump DesignOriginal File Name Searched:
Reclaim-CO2-HWHP-design-guide-v2.pdfDIY PDF Search: Google It | Yahoo | Bing
CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info