PDF Publication Title:
Text from PDF Page: 165
5 – Experimental Results Combined Mode DHW Mode SH Mode 3.98 3.80 3.89 3.80 3.86 3.80 3.15 3.01 2.78 DHW 60oC 0.49 0.57 0.69 SH 33/28°C SH 35/30°C SH 40/35°C Combined Mode DHW Mode SH Mode 3.75 3.58 3.57 3.58 3.50 3.58 3.15 3.01 2.78 DHW 70oC 0.43 0.43 0.62 SH 33/28°C SH 35/30°C SH 40/35°C Combined Mode DHW Mode SH Mode 3.57 3.20 3.15 SH 33/28°C 3.44 3.20 3.01 3.24 3.20 2.78 DHW 80oC 0.31 0.39 0.52 SH 35/30°C SH 40/35°C Figure 5.38 The measured maximum COP for the CO2 heat pump unit at varying temperature levels for the space heating and hot water systems. The DHW heating capacity ratio for each temperature programme is shown in the middle of the bars. 143PDF Image | Residential CO2 Heat Pump System for Combined
PDF Search Title:
Residential CO2 Heat Pump System for CombinedOriginal File Name Searched:
20559406.pdfDIY PDF Search: Google It | Yahoo | Bing
CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info
Heat Pumps CO2 ORC Heat Pump System Platform More Info
CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com (Standard Web Page)