Text from PDF Page: 009

Applications – Combination Heating and DHW It is permitted to use the SANCO2 system to provide some limited capacity heating (radiant, fan coil, etc.) in certain areas of North America, when combined with a minimum of 25 gallons per day usage of DHW. It is NOT permitted to use the SANCO2 system to provide heating as its only function. Sizing Maximum heating capacity must be less than 8,000 BTU/h. Minimum design ambient temperature must be above 27°F. Tank size must be the 83 gallon tank. DHW usage – minimum 25 gallons per day. Installation Like residential applications, the heat pumps and tanks can be installed indoor and/or outdoor depending on a building design, location, and climate. Installation location specifics must be as per the residential application. Important Per your local code, potable and non-potable water may need to be separated. Check with your local code authority to determine if separation, and/or use of a double wall heat exchanger is required. In applications requiring separation between potable and non-potable water, Sanden mandates the use of a Taco X-block system. It is very important to install a combination system using the plumbing schematic developed by Sanden. Particular importance must be given to the location of the heating system return water pipe from the X-block to the tank, lower return water temperatures should return to the bottom of the tank. Detailed planning and a meticulous installation is required, especially with multiple units piped together so that the entire installed system will function as it is intended. 9

PDF Image | Sanden SANCO2 Heat Pump Water Heater 2017

sanden-sanco2-heat-pump-water-heater-2017-009

PDF Search Title:

Sanden SANCO2 Heat Pump Water Heater 2017

Original File Name Searched:

Sanden_sanc02_technical-info_10-2017_4.pdf

DIY PDF Search: Google It | Yahoo | Bing

CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info

Heat Pumps CO2 ORC Heat Pump System Platform More Info

CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com | RSS | AMP