APPENDIX A – TYPICAL INTERCONNECTION AGREEMENT DATA The table below provides typical data requested during an interconnection study or interconnection agreement application. Prime Mover Manufacturer Model Name Pratt & Whitney Power Systems PureCycle Model 280 Power System Induction Baldor Electric Company, Greenville, SC Model V02XR24001725GN 0.296 gross output of generator 0.280 gross out put of generator Internal PFC capacitors provided to yield pf ~ 0.95 at rated power 480 volt + 10%, -12% 100% rated operation 0.347 sec N/A This is an induction generator system that will operate only in grid synchronization. Upon loss of the grid, the system will shut down. UV 88%, OV 110% UF 57 Hz OF 60.5 Hz UV 2 seconds, OV 1 seconds UF 10 cycles, OF 10 cycles N/A Induction Generator Beckwith Electric Company Model 3410A or equivalent; customer provided A. B. C. D. E. F. G. Type of generating unit Manufacturer Rated MVA Maximum gross output (MW) Rated lagging power factor Nominal voltage and acceptable voltage range (volts ±%) Estimated load factor, number of hours/year of operation or MWh/year Stability Data: 1. Inertia of turbine/generator (sec) 4. Governor data and Laplace transform block diagrams of the control equipment VOLTAGE/FREQUENCY LIMITS 1. Pickup settings 2. Transient direct axis reactance (PU) See generator data sheet A. Substransient Reactance = 0.1345 B. SC time constant = 0.050 sec C. OC time constant = 2.193 sec 3. Excitation system data Internal PFC capacitors provided to yield pf ~ 0.95 at rated power, utility or customer to provide balance of reactive power. System operates only in grid parallel mode. H. 2. Roll off rates I. Minimum/maximum excitation limits K. Interconnection protective relay J. Interconnecting circuit breaker (disconnect switch) 1. Manufacturer 2. Load rating, interrupting rating Siemens Model SHMD69600A 600 A Load Rating, 65 KAIC Fault Rating The customer will typically be asked to provide one-line block diagrams and site layouts showing the generator interconnection to the existing facility as well as the grid interconnection. Additional questions typically asked by the interconnecting utility include those listed below. Answers will vary by site. Please contact your Pratt & Whitney Power Systems representative for further assistance. 1. Is the application for new generating capability or an addition to existing generating capability? 2. Is there net metering? 3. Will the power be used to supply power to the interconnection customer (will the power be consumed on-site)? 4. Will the power be used to supply power to others (exported to the interconnecting utility grid)? If so, how much power is expected to be exported? 5. Will a transformer be used between the generator and the point of common coupling? If so, the customer should be prepared to provide information on the transformer. Revision B – 09/23/2009 – Page 29 HTE66510

PDF Image | PURECYCLE POWER SYSTEM MODEL 280 Application Guide

PDF Search Title:

PURECYCLE POWER SYSTEM MODEL 280 Application Guide

Original File Name Searched:

Purecycle_application_guide.pdf

DIY PDF Search: Google It | Yahoo | Bing

NFT (Non Fungible Token): Buy our tech, design, development or system NFT and become part of our tech NFT network... More Info

IT XR Project Redstone NFT Available for Sale: NFT for high tech turbine design with one part 3D printed counter-rotating energy turbine. Be part of the future with this NFT. Can be bought and sold but only one design NFT exists. Royalties go to the developer (Infinity) to keep enhancing design and applications... More Info

Infinity Turbine IT XR Project Redstone Design: NFT for sale... NFT for high tech turbine design with one part 3D printed counter-rotating energy turbine. Includes all rights to this turbine design, including license for Fluid Handling Block I and II for the turbine assembly and housing. The NFT includes the blueprints (cad/cam), revenue streams, and all future development of the IT XR Project Redstone... More Info

Infinity Turbine ROT Radial Outflow Turbine 24 Design and Worldwide Rights: NFT for sale... NFT for the ROT 24 energy turbine. Be part of the future with this NFT. This design can be bought and sold but only one design NFT exists. You may manufacture the unit, or get the revenues from its sale from Infinity Turbine. Royalties go to the developer (Infinity) to keep enhancing design and applications... More Info

Infinity Supercritical CO2 10 Liter Extractor Design and Worldwide Rights: The Infinity Supercritical 10L CO2 extractor is for botanical oil extraction, which is rich in terpenes and can produce shelf ready full spectrum oil. With over 5 years of development, this industry leader mature extractor machine has been sold since 2015 and is part of many profitable businesses. The process can also be used for electrowinning, e-waste recycling, and lithium battery recycling, gold mining electronic wastes, precious metals. CO2 can also be used in a reverse fuel cell with nafion to make a gas-to-liquids fuel, such as methanol, ethanol and butanol or ethylene. Supercritical CO2 has also been used for treating nafion to make it more effective catalyst. This NFT is for the purchase of worldwide rights which includes the design. More Info

NFT (Non Fungible Token): Buy our tech, design, development or system NFT and become part of our tech NFT network... More Info

Infinity Turbine Products: Special for this month, any plans are $10,000 for complete Cad/Cam blueprints. License is for one build. Try before you buy a production license. May pay by Bitcoin or other Crypto. Products Page... More Info

CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com (Standard Web Page)