Text from PDF Page: 017

TECHNOLOGY OVERVIEW Figure 3: COMBINATION SYSTEMS THERMOLIFT (LICENSING) 140% AFUE Target Whole-house (heating/cooling/DHW) Potential sizing ~60 kBtu/hr with 3:1 modulation Recent lab test suggests COP_Gas = 1.52 at A8.3 Building alpha prototypes for expanded testing in 2019 SALTX (OEM SUPPLIER) 135% AFUE Target Partner with DOE Whole-house (heating/DHW) Potential sizing 50 kBtu/hr with 4:1 modulation Alpha prototype projected Q1 2020 ~130% AFUE (projected in EU) Whole-house Combi (Heating/DHW) Heating (48 kBtu/h) w/boiler backup Recently discontinued in EU VIESSMAN (DIRECT TO MARKET) LABORATORY (3-5 YEARS) ROBUR (DIRECT TO MARKET) 130% AFUE (cert. in EU) Large whole-house Combi (Heating/DHW) Heating (64 kBtu/h) Available in EU only VALLIANT (DIRECT TO MARKET) ~128% AFUE (cert. in EU) Whole-house Combi (Heating/DHW) Heating (51 kBtu/h) with boiler backup Recently discontinued in EU, likely due to limited product offerings, high equipment costs and low market adoption ~125% AFUE (cert. in EU) Whole-house Combi (Heating/DHW) Heating (51 kBtu/h) w/boiler backup Recently discontinued in EU, likely due to limited product offerings, high equipment costs and low market adoption VIESSMAN (DIRECT TO MARKET) COMMERCIALIZED BOSCH/JUNKERS (DIRECT TO MARKET) BOOSTHEAT (DIRECT TO MARKET IN EU) ARISTON (DIRECT TO MARKET) FIELD DEMOS / SCALE UP (0-3 YEARS) Presented by: Brio and GTI 17 SMTI (OEM Supplier) Installed as hybrid system with multiple outputs, heating, hot water, A/C all feasible 140% AFUE expected and 20% electricity savings for A/C estimated (where applied) Up to 140 kBtu/hr output 4:1 modulation Pilots in CA, IL >130% AFUE (projected in EU) Whole-house combi (Heating/DHW) Heating (61 kBtu/h) w/ boiler backup 4:1 modulation Commercialization effort halted in 2018 ~160% AFUE (estimate) Whole-house Combi (Heating/DHW) Heating (68 kBtu/h) with boiler backup Certified with 1.65 COP_Gas at A7/W35 Recent industrialization in partnership SMTI (OEM SUPPLIER) 140% AFUE Whole-house combi (heating/DHW) Low-load (20 kBtu/h) Cold-climate (80 kBtu/h); 4:1 modulation; ultra-low NOx (cert.) Pilots in TN, WI ~140% AFUE (projected in EU) Whole-house combi (heating / DHW) Heating (34 kBtu/h) with boiler backup Currently exploring expansion with alternative suppliers Residential Current/projected availability in US/Canada Commercial Current/projected availability outside US/Canada INCREASING SCALE TECHNOLOGY MATURATION

PDF Image | GAS HEAT PUMP TECHNOLOGY AND MARKET ROADMAP

gas-heat-pump-technology-and-market-roadmap-017

PDF Search Title:

GAS HEAT PUMP TECHNOLOGY AND MARKET ROADMAP

Original File Name Searched:

2019-heat-pump-roadmap.pdf

DIY PDF Search: Google It | Yahoo | Bing

CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info

Heat Pumps CO2 ORC Heat Pump System Platform More Info

CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com | RSS | AMP