Table 1. Capacity-specific refrigerant content of four types of heat pumps. Heat Pump Type Refrigerant GWP Pounds of Refrigerant per 12,000 BTU/hr Heating Capacity Packaged or field-assembled refrigerant circuit Refrigerant leak risk Space Heating PTHPa WSHPb Small split system – ccASHPc R410 VRFd R32 Hybrid Water+VRFe R410 Hybrid Water +VRFf Domestic Hot Water Residential DHW HPWHg Central AWHPh R410a R410a R410a R410a R32 R410a R744 R134a 2088 2.2 2088 2.2 2088 2.6 2088 3.7 to 10 26 675 1 to 2.5 2088 1 to 4 1 1 1,400 0.7 Packaged Packaged Field-assembled Field-assembled Field-assembled Field-assembled Packaged Packaged Indoor coil Indoor coil Field-assembled piping and indoor coil Field-assembled piping and indoor coil Field-assembled piping and indoor coil Field-assembled piping and indoor coil Outdoor unit Outdoor unit a Based on Islandaire EZED15, heating capacity: 12,290 BTU/hr, R410a content: 36.3 ounces b Based on ClimateMaster TRC, heating capacity: 9,500BTU/hr, R410a content: 28 ounces c Based on Fujitsu 18RLX, heating capacity: 21,600 BTU/hr, R410a content: 74.1 ounces d Based on Fujitsu Airstage V-II, heating capacity: 81,000 BTU/hr, R410a content: 395.2 ounces e Based on Mitsubishi R32 HVRF R2, heating capacity 127,950 BTU/hr, R32 content: 183.5 ounces – 448 ounces f Based on Mitsubishi R410 HVRF R2, heating capacity 127,950 BTU/hr, R410a content: 183.5 ounces – 1334 ounces g Based on Sanden SanCO2, heating capacity 15,400 BTU/hr, R744 content: 22 ounces h Based on Colmac HPA15, heating capacity 267,100 BTU/hr, R134a content: 250 ounces Steven Winter Associates,Inc. 8

PDF Image | HEAT PUMP RETROFIT STRATEGIES FOR MULTIFAMILY BUILDINGS

PDF Search Title:

HEAT PUMP RETROFIT STRATEGIES FOR MULTIFAMILY BUILDINGS

Original File Name Searched:

heat-pump-retrofit-strategies-report-05082019.pdf

DIY PDF Search: Google It | Yahoo | Bing

CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info

Heat Pumps CO2 ORC Heat Pump System Platform More Info

CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com (Standard Web Page)