PDF Publication Title:
Text from PDF Page: 025
and evaporation temperature. Both experimental and simulation approaches were used. Different tests were done by varying these parameters and as per the stated results the optimum high side pressure was more sensitive to the CO2 gas cooler outlet temperature while the degree of superheat has negligible influence. The experimental setup was having counter flow tube in tube type heat exchangers as evaporator and gas cooler. 13PDF Image | heat recovery from R744 based refrigeration system
PDF Search Title:
heat recovery from R744 based refrigeration systemOriginal File Name Searched:
r744-heat-recovery.pdfDIY PDF Search: Google It | Yahoo | Bing
CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info