Text from PDF Page: 026

(2) Table of settings items Set the dip switches SW2 and SW3 as shown in the table below to set the value for the items in the "Setting item" column. Dip switch settings Setting item Item code Unit Lower limit Upper limit Initial value Setting value Basic settings SW2-10: OFF SW3-5, 6, 7: OFF SW3-8, 9, 10: ON Unit address 105 - 1 8 2 Number of connected GS to M-NET 106 - 0 16 1 AE-200 connection (0: Not connected, 2: Connected) 107 - 0 2 0 Function 1 (Sub sensor: 2, Main sensor: 1, Sub unit: 0) 110 - 0 2 0 M-NET address of main sensor of own tank 111 - 1 50 1 Address of sensor connection unit 112 - 1 51 51 Secondary control availability (0: Not available 1: Available) 121 - 0 1 0 Basic settings SW2-10: OFF SW3-5~8, 10: OFF SW3-9: ON Model display 0 - - - - Current time 1 Hour and minutes 0:00 23:59 - Current inlet water temperature (display function only) c01 oC - - - Current outlet water temperature (display function only) c02 oC - - - Outdoor temperature (display function only) c03 oC - - - Storage tank water temperature (display function only) c04 oC - - - Demand control - maximum capacity setting 2 % 0 100 100 Demand control - start time 3 Hour and minutes 0:00 23:59 13:00 Demand control - end time 4 Hour and minutes 0:00 23:59 16:00 Outlet hot water temperature (boiling temperature) 9 oC 40 Secondary contlol disabled: 90.0 Secondary contlol enabled: 80.0 65 High- and low-pressure display interval P 1051 Seconds 0 100 3 Low noise operation - maximum capacity 1054 % 0 100 70 Low noise operation - start time 1058 Hour and minutes 0:00 23:59 0:00 Low noise operation - end time 1059 Hour and minutes 0:00 23:59 0:00 SW2-10: OFF SW3-5~7, 9, 10: OFF SW3-8: ON Thermo-ON prohibition time Sjs1 1025 Seconds 0 480 60 Sensor method setting (0: Local control, 1: Three-sensor, 2: Six-sensor) 1214 - 0 2 0 Mode 1 Thermo-ON thermistor selection 1500 - 1 Six-sensor system: 6 Other system: 3 3 Mode 1 Thermo-OFF thermistor selection 1501 - 1 Six-sensor system: 6 Other system: 3 3 Mode 2 Thermo-ON thermistor selection 1502 - 1 Six-sensor system: 6 Other system: 3 1 Mode 2 Thermo-OFF thermistor selection 1503 - 1 Six-sensor system: 6 Other system: 3 2 Mode 3 Thermo-ON thermistor selection 1504 - 1 Six-sensor system: 6 Other system: 3 1 Mode 3 Thermo-OFF thermistor selection 1505 - 1 Six-sensor system: 6 Other system: 3 3 Number of water control modes 1507 - 1 3 1 Mode 1 Thermo differential value 1508 - 0 30 10 Mode 2 Thermo differential value 1509 - 0 30 10 Mode 3 Thermo differential value 1510 - 0 30 10 Anti-freezing setting (0: Outdoor, 1: Indoor) 1514 - 0 1 0 26

PDF Image | QAHV-N560YA-HPB

PDF Search Title:

QAHV-N560YA-HPB

Original File Name Searched:

IBIM_WT08219X05_QAHV_N560YA_HPB_ML.pdf

DIY PDF Search: Google It | Yahoo | Bing

CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info

Heat Pumps CO2 ORC Heat Pump System Platform More Info

CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com (Standard Web Page)