5 – Experimental Results Figure 5.56 shows the measured thermocline between the hot and cold water reservoirs in the DHW tank. The initial temperatures of the water reservoirs were 53.2 and 4.8oC, respectively, and the average room tempe- rature during the 12 hour test period was 22.5oC. The vertical position of the temperature sensors refers to the distance between the sensors and the stainless steel plate that separated the water reservoirs in the tank (ref. Section 4.2.2.3). 30 25 20 15 10 5 0 -5 -10 -15 -20 -25 -30 8 h 2h Start Start 1h 4h 12 h T m 0 10 20 30 40 50 60 Temperature [°C] Figure 5.56 The measured thermocline in the 200 litre DHW tank. The initial water temperatures were 53.2 and 4.8oC, and the average room temperature during testing was 22.5oC. 162 Vertical Position [cm]

PDF Image | Residential CO2 Heat Pump System for Combined

residential-co2-heat-pump-system-combined-184

PDF Search Title:

Residential CO2 Heat Pump System for Combined

Original File Name Searched:

20559406.pdf

DIY PDF Search: Google It | Yahoo | Bing

CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info

Heat Pumps CO2 ORC Heat Pump System Platform More Info

CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com | RSS | AMP