shows the work input (which is equal to the availability of the feed gas at PH) divided into three streams by the PSA system. The middle bar, which represents the availability of the product stream, is taken to be the availability of the pure oxygen product at the pressure PH. This availability includes the difference in pressure between the product stream and the ambient air (PH = 15.6 arm and Po = 1 arm, respectively), and the difference in composition between the product stream and the ambient air (yp = 0 and yo = 0.78, respectively). The equation for this is Equation (4.1). NP2 RT In PH^-yp) 0 (4.1) N P2 The bottom bar represents the availability of the exhaust stream, which Banerjee calculates to be 17,000 J/mol O2. The equation that I have used in the following section for the availabiHty of the exhaust stream per mole of product is Equation (4.2). Using this equation, I cannot arrive at the same value given by Banerjee; my calculation yields \|/B =333J/mol02. RTn +N In (4.2) ¥E=N EB 1-JV P2 yy0) The first term in Equation (4.2) is positive and the second is negative, as the exhaust stream is enriched in species A and depleted in species B. Even if both terms are taken as positive, the value of I|/E is 3733 J/mol O2 which is still much lower than the value given by Banerjee. However, my analysis, which follows, is not dependent on Banerjee's results. 102PDF Image | Energy Efficiency of Gas Separation Pressure Swing Adsorption
PDF Search Title:
Energy Efficiency of Gas Separation Pressure Swing AdsorptionOriginal File Name Searched:
ubc_1997-0009.pdfDIY PDF Search: Google It | Yahoo | Bing
CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info
Heat Pumps CO2 ORC Heat Pump System Platform More Info
CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com | RSS | AMP |