APPENDIX D MINIMUM BSF EXPERIMENTS D.1. Tabulated experimental results for minimum BSF study Table D1. Long columns experimental results, pressure ratio 3.5 Cycle 1 Cycle 2 Cycle 3 Cycle 4 Cycle 5 Cycle 6 Cycle 7 Cycle 8 Cycle 9 Total cycle time (s) 6 3.9 3.3 3.2 6 4.2 3.36 3.12 5.28 % Oxygen Recovery 18.8 14.3 12.7 11.0 19.4 15.3 12.2 11.1 17.0 BSF (lbs. solid/TPD O2) 140 119 116 132 138 123 123 126 140 Pressure ratio 3.5, P/F ratio 0.45, product purity 96%, oxygen production step pressure ~195 kPa 170

PDF Image | LIMITS OF SMALL SCALE PRESSURE SWING ADSORPTION

PDF Search Title:

LIMITS OF SMALL SCALE PRESSURE SWING ADSORPTION

Original File Name Searched:

Limits of Small Scale PSA_Aaron Moran.pdf

DIY PDF Search: Google It | Yahoo | Bing

CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info