Table 11. Conversion factor and cell density for the mixed LixAgy-zeolites. Sorbent Li94.5Na1.5-LSX Li94.2Ag1.1Na0.7-LSX Li92.0Ag3.5Na0.5-LSX Li83.9Ag11.5 Na0.6-LSX Li73.8Ag21.0 Na1.2-LSX Ag9.7Na0.3-LSX Ag85.7Na0.3-X Conv. Factor (g molec/mmol uc) 12.12047 12.21865 12.45768 13.26673 14.23573 21.76031 20.69265 cell density (g/uc) x 1020 2.012 2.029 2.068 2.203 2.363 3.613 3.436 115PDF Image | PSA USING SUPERIOR ADSORBENTS
PDF Search Title:
PSA USING SUPERIOR ADSORBENTSOriginal File Name Searched:
789503.pdfDIY PDF Search: Google It | Yahoo | Bing
CO2 Organic Rankine Cycle Experimenter Platform The supercritical CO2 phase change system is both a heat pump and organic rankine cycle which can be used for those purposes and as a supercritical extractor for advanced subcritical and supercritical extraction technology. Uses include producing nanoparticles, precious metal CO2 extraction, lithium battery recycling, and other applications... More Info