1MW ROT Radial Outflow Turbine ROT ORC

Infinity Turbine 1 MW ROT Turbine with Three Stages over dual rotors

Radial Outflow Turbine 1MW AC Generator Hermetically Sealed

Infinity Turbine now has a megawatt ORC radial outflow concept turbine.

IT1000 (1 MW) Revenue based on gross sales or savings, not including cost of acquiring waste heat flow or pumps.

Revenue from IT250 (24 hours x 365 days per year x 1000 kWh = 8,760,000 kWh per year):

at $.20 per kWh = $1,752,000 USD per year

at $.40 per kWh = $3,504,000 USD per year

at $.80 per kWh = $7,008,000 USD per year

Email: 1 MW ROT Info


Infinity Turbine 1 MW ROT Turbine Dual 24 inch diameter rotors with 12 inch stack height with three stages

Radial Outflow Turbine 1MW AC Generator Hermetically Sealed

Using a scaled up version of existing ROT technology, this design may produce 1 megawatt of power. Turbine would operate at full load speed of 3600 rpm. Turbine is direct mounted to an induction generator (2-pole). Due to the large size of the generator, it is likely a higher voltage than typical (2400V+) and would probably need to be direct grid connect because grid tie controllers cannot be found in this size or voltage. Size of generator likely to be 31in OD and needs a custom cast iron housing for direct refrigerant cooling.

Construction of plates and turbine are possible using current manufacturing capabilities. Large cast iron housings are likely to be outsourced to a vendor (several available). Generator may be an induction motor from a chiller motor supplier (operating in reverse) if no generator suppliers can be found.

Email: 1 MW ROT Info


Infinity Turbine 1 MW ROT Turbine with Dual Rotors

Bearings

Bearings are oil lubricated and use lip seals to keep the oil separated from refrigerant system.

Email: 1 MW ROT Info


Infinity Turbine 1 MW ROT Turbine Flow Diagram

Working Pressure 200 PSIG

Design Working Pressure is to be 200 psig and refrigerant is to be R245fa.

Email: 1 MW ROT Info


1 MW ROT Turbine with Dual Rotors that have Three Stages each

Heat Exchanger Design Requirements

Heat exchanger design should be 212F (evap water in), 95F (condenser water in), 20 F ranges and 20 F approaches. This requires 125 lbm/s refrigerant flow and provides 10 persent system efficiency (Evap heat = 30,000,000 Btu/hr).

Oversize the condenser for better cooling. To save on manufacturing, make both evaporator and condenser same size to take advantage of economies of scale.

Turbine is dual sided ROT with 3 stages (4.5 inch blade heights per side). Overall Diameter is 24in.

Designed to produce 1MW output

Email: 1 MW ROT Info


Infinity Turbine 1 MW ROT Turbine with Two Stages 74 inches x 46 inches

Dimensions of Turbine Assembly and Rotors

Overall turbine generator housing assembly dimensions are 74 inches (1880 mm) in length.

Overall frontal area is 46 inches (1168 mm) by 37 inches (940 mm).

Turbine Blade Height: 4.5 inches (114 mm)

Turbine Rotor Diameter: 24 inches (609.6)

Turbine Blades Manufacturing: CNC or may be 3D metal printed with slotted fastened rotor disc attachment. There are also waterjet stacking layer options to reduce machining time significantly.

Spin: 3,600 RPM

Generator: 2 pole

2,400 V +

Generator Diameter: 31 inches diameter (787 mm)

Generator Type: Induction or Synchronous

Bearings: Oil lubricated lip seals to keep refrigerant separate from refrigerant (working fluid) in the system.

Email: 1 MW ROT Info


Infinity Turbine 1 MW ROT Turbine Dimensions 37 x 46 inches

Email: 1 MW ROT Info


QUICK LINK Fast reference section for Infinity Turbine MENU

Turbine and System Plans CAD CAM $10,000: Special for this month, any plans are $10,000 for complete Cad/Cam blueprints. License is for one build. Try before you buy a production license. Products Page... More Info

AI Server Farm Cooling Technology, Strategies, and Plans for modular Container and Van Mounted Miner Facilities: Have cooling issues ? We have some interesting cost saving solutions including plans and consulting...

Strategy and Energy Consulting Services: System sizing, ORC payback, renewable energy strategy, PID diagrams. Crypto mining (ASIC and GPU) and energy savings... More Info

Sand Battery Sand Battery for thermal storage More Info

Waste Heat Power Technology Using ORC Organic Rankine Cycle: The ORC unit is a system based on a closed-loop thermodynamic cycle for the generation of electric and thermal power, especially suitable for distributed generation. ORC systems can generate electric and thermal power exploiting multiple sources, such as renewables (biomass, geothermal energy, solar energy, GPU waste heat), traditional fuels and waste heat from industrial processes, waste incinerators, engines or gas turbines. More Info

Flow Battery New designs for electric energy storage More Info

All Turbine and System Products Listing: Listing of all turbine and other Infinity Turbine machine designs. Cryptocurrency now accepted. Infinity Turbine ORC systems, turbine generator sets, build plans and more to use your waste heat from 30C to 100C. More Info

CONTACT TEL: 608-238-6001 Email: greg@infinityturbine.com (Standard Web Page) | PDF | IG