IT50 Waste Heat to Power System by Infinity Turbine

QUICK LINK Fast reference section for Infinity Turbine MENU

New Development Converting 10L Supercritical CO2 Machines to Produce Liquid Nitrogen and Oxygen: Infinity is now working on converting the 10L extraction systems to produce Liquid Nitrogen (LN2) and Liquid Oxygen (LOX). These valuable gases can be used for rockets, cooling lasers, and cryogenic botanical extraction. More Info

IT50: 50 kW ORC system plans or complete system. More Info

Strategy and Consulting Services: System sizing, ORC payback, renewable energy strategy, PID diagrams. More Info

Turbine and System Plans CAD CAM: Special for this month, any plans are $10,000 for complete Cad/Cam blueprints. License is for one build. Try before you buy a production license. More Info

Waste Heat Power Technology: Organic Rankine Cycle uses waste heat to make electricity, shaft horsepower and cooling. More Info

Video: YouTube Link More Info

CO2 + H2O + DC Electricity + Nafion = Plastics and Fuel GTL Gas to Liquids Developers and Experimenters System Cart... More Info

Hydrodynamic Cavitation: Use our Modular Block technology and water to make Silver Nanoparticles and even use for hemp oil extraction. More Info

All Turbine and System Products: Infinity Turbine ORD systems, turbine generator sets, build plans and more to use your waste heat from 30C to 100C. More Info

Email: greg@infinityturbine.com

TEL: 608-238-6001

IT50 System

IT50 System

Infinity Turbine IT50 System for AC Power from Waste Heat

The IT50 is designed to produce 50 kW of AC power (typically configured for a Grid-Tie connection). We have produced several IT50 systems in the past few years. They take about 6 months to complete, and can be shipped in a standard 20 ft. shipping container.

Currently we can complete this build through our sub-contractor who builds ASME certified pressure tested heat exchangers in Toronto, Canada, and ship anywhere in the world.

Design Heat Exchangers ASME Rated Pressure - Evaporator R-245fa: 450 psi at 300 F shell side, and 150 psi 300 F on tube side. Welding procedures included. Condenser R-245fa: 450 psi at 250 F shell side, and 150 psi 250F on tube side.

Turbine may be used most efficiently at 50 kW, but may also be used for a range of turbines from 30 kW to over 100 kW. Plans Option for IT50

IT50 Loaded into a 20 ft Shipping Container

IT50 Loaded into a 20 ft Shipping Container

Grid Tie Device

Our induction AC generators require a grid tie device, which can be found on the link below from Sieb Meyer in Germany. Grid Tie Device

IT50 Completed System

IT50 Completed System

IT50 System Purchase Details

IT50 Organic Rankine Cycle System with ROT turbine and 50 kW output generator.

Standard complete system, which will accept 80-110 deg C input thermal fluid.

Heat exchangers are ASME designed and build by Henry Technologies in Canada.

Unit ships without refrigerant. 50-60 hz 380-480 (approx) V AC Generator.

Designed for R245fa. You may use R134a, proper cooling will be required. Unit includes a AC induction (asynchronous) generator, which will require the use of a grid-tie device to operate.

Unit has basic PLC for monitoring operating temperatures and pressures, but unit is really controlled by the grid-tie device, which senses output power and will adjust the VFD feedpump, which ultimately controls the turbine rotor speed. See: http://www.sieb-meyer.de Sieb Meyer

Completed IT50 System

Completed IT50 System

IT50 Scope of Supply

Please see our Scope of Supply for the IT50. This will be updated with new purchase to reflect any new technology or components. IT50 Scope of Supply

IT50 System Software

IT50 System Software

IT50 System Software Run Mode

IT50 System Software Run Mode

IT50 Performance Curve

IT50 Performance Curve