IT50 Waste Heat to Power System ORC

IT50 System Performance

IT50 System Plans

Infinity offers both the ROT turbine plans and the IT50 system plans as a separate package.

We recommend the ROT24 for the IT50, even if it is de-rated.

Design Heat Exchangers ASME Rated Pressure - Evaporator R-245fa: 450 psi at 300 F shell side, and 150 psi 300 F on tube side. Welding procedures included. Condenser R-245fa: 450 psi at 250 F shell side, and 150 psi 250F on tube side.

Turbine may be used most efficiently at 50 kW, but may also be used for a range of turbines from 30 kW to over 100 kW.

IT50 Revenue based on gross sales or savings, not including cost of acquiring waste heat flow or pumps.

Revenue from IT50 (24 hours x 365 days per year x 50 kWh = 438,000 kWh per year):

at $.20 per kWh = $87,600 USD per year

at $.50 per kWh = $219,000 USD per year

at $1.00 per kWh = $438,000 USD per year

Contact Infinity for pricing.

ROT24 Radial Outflow Turbine ROT ORC

IT50 Waste Heat to Power System ORC

IT50 Waste Heat to Power ORC


IT50 Build Plans

Build Plans

All licensing allows you to scale up or down in sizes, which allows you to build smaller systems, or number up for larger system capacities.


IT50 Electrical Conduit


IT50 System Control


IT50 Software


ROT24 Turbine Rotor and Stator


IT50 System


IT50 System Completed


INFINITY TURBINE | SALES | DESIGN | DEVELOPMENT | ANALYSIS CONSULTING

TEL: +1-608-238-6001 (Chicago Time Zone )

Email: greg@infinityturbine.com

ElectraTherm 125 kWe ORC and Hurst Boiler For Sale | Biomass and Waste Heat to Energy This pre-packaged 40-foot container combines a 125 kWe Organic Rankine Cycle generator with an industrial Hurst boiler to deliver grid-ready electricity from heat that would otherwise be wasted. With minimal runtime and turnkey integration, this mobile energy platform enables rapid deployment for biomass systems, industrial facilities, and distributed power projects where reliable on-site generation is required. More Info

IT1000 Supercritical CO2 Gas Turbine Generator Silent Prime Power 1 MW (natural gas, solar thermal, thermal battery heat) ... More Info

Supercritical CO2 Turbine TDK Technology Development Kit Use our base tech and make your own IP for Data Center Prime Power Generators using Natural Gas or using Waste Heat... More Info

ORC and Products Index Infinity Turbine ORC Index... More Info

CONTACT TEL: +1-608-238-6001 (Chicago Time Zone USA) Email: greg@infinityturbine.com (Standard Web Page) | PDF