TEL: 1-608-238-6001 Email: greg@infinityturbine.com
Special Until October 2024: Turbine and ORC Licensing - Try Before You Buy Build one system or turbine-generator, then decide on the license More Info
Grid-Scale Saltwater Flow Battery by Salgenx 3000 kWh to 18 MWh The new competitor for the Tesla Megapack. Flow Battery using a variety of cathode materials which include Zinc, Bamboo, Vermiculite, and more. Mfg for less than $100/kWh. 3000 kWh Grid Scale Battery. Use for peaker plants or Data Centers. More Info
Data Center Energy Strategies Using Cluster Mesh Power Generation Learn more about CMPG for cooling and power strategies for Data Centers for the Cloud, AI, and Crypto More Info
Microturbine APP and Spreadsheet by Global Energy Global Energy has developed an App and Spreadsheet for Capstone Turbine and Capstone Green Energy microturbine parts where you can buy OEM supplier direct to save money on parts purchases especially for the C200... for iPhone, iPad, and desktop Mac/Windows More Info
ORC Radial Outflow Turbine Kit Infinity Turbine is now offering a ROT Radial Outflow Turbine for customer assembly flat pack kit. Save thousands compared to completed turbine generator... More Info
Data Centers Cooling and Power Strategies Technology Report More Info
Diesel Generator ORC Power Produced in kW |
Utilizing waste heat from Diesel Generators to make free power. Taking waste heat from diesel generators can produce free power in a Organic Rankine Cycle (ORC) system. The sources of waste heat are engine cooling (replacing large coolant system fan) and stack exhaust which is normally waste heat to the atmosphere. The ORC does require a cool liquid condenser flow, but generally can utilize the waste heat from the diesel engine to provide 28 percent savings. Generally a 500 kW diesel or larger are prime candidates for utilizing waste heat to make power.Exhaust to Power: With an additional waste heat to thermal oil heat exchanger, you can capture the diesel exhaust from the pipe to supply heat to the Infinity turbine. This is about 40 percent of total fuel savings as shown in chart below.Coolant to Power: Pipe straight to the Infinity turbine. This is about 32 percent of total fuel savings as shown in chart below. IT250 Revenue based on gross sales or savings, not including cost of acquiring waste heat flow or pumps.Revenue from IT250 (24 hours x 365 days per year x 250 kWh = 2,190,000 kWh per year):at $.20 per kWh = $438,000 USD per yearat $.40 per kWh = $876,000 USD per yearat $.80 per kWh = $1,752,000 USD per yearIT1000 (1 MW) Revenue based on gross sales or savings, not including cost of acquiring waste heat flow or pumps.Revenue from IT250 (24 hours x 365 days per year x 1000 kWh = 8,760,000 kWh per year):at $.20 per kWh = $1,752,000 USD per yearat $.40 per kWh = $3,504,000 USD per yearat $.80 per kWh = $7,008,000 USD per year Diesel Generator ORC Waste Heat Power Available (pdf)
|
Diesel Generator ORC Power Savings Per Year |
Savings Utilizing a ORC on the waste heat from a Diesel Generator If you run a diesel generator set or any of the engines below 24/7, you may be able to capture the waste heat to generate additional kilowatts of electricity. In addition, you may reduce or eliminate the HP need to drive your radiator coolant fan.Exhaust to Power: With an additional waste heat to thermal oil heat exchanger, you can capture the diesel exhaust from the pipe to supply heat to the Infinity turbine. This is about 40 percent of total fuel savings as shown in chart below. For a 100 kilowatt Prime diesel genset, this is about 8 kWe per hour additional power. Savings calculated at $4.50 per gallon.Coolant to Power: Pipe straight to the Infinity turbine. This is about 32 percent of total fuel savings as shown in chart below. For a 100 kilowatt Prime diesel genset, this is about 7 kWe per hour additional power. Savings at $4.50 per gallon. Savings Per Year Using Waste Heat from a Diesel Generator (pdf)
|