ORC Refrigerants at 300 psi: Temperature Limits, Efficiency, and Usage Notes
ORC Refrigerants at 300 psi: Temperature Limits, Efficiency, and Usage Notes
Note: the standard Infinity Turbine ORC systems are designed for 300 psi operation. If you want higher pressure, then consider our Supercritical CO2 systems.IntroductionIn Organic Rankine Cycle (ORC) systems, the thermodynamic properties of refrigerants determine efficiency, operating conditions, and overall system performance. By comparing refrigerants at a standard pressure of 300 psi (~20.7 bar), we can evaluate how temperature capability, efficiency, and practical use cases differ. This article lists common ORC refrigerants, their temperature at 300 psi, Carnot efficiencies at those temperatures, optimal condenser ranges, and regulatory notes.R-245fa (Honeywell Genetron)Temperature at 300 psi (20.7 bar): ~125 °C (257 °F)Carnot Efficiency (vs 30 °C / 86 °F condenser): ~25 percentCondenser Temperature: Most effective around 30–35 °C (86–95 °F)Notes: High global warming potential (GWP ~950). Facing phase-out in the EU under F-Gas Regulation.R-1233zd(E) (Hydrofluoro-olefin, HFO)Temperature at 300 psi (20.7 bar): ~155 °C (311 °F)Carnot Efficiency (vs 30 °C / 86 °F condenser): ~29 percentCondenser Temperature: Effective in the 25–35 °C (77–95 °F) rangeNotes: Very low GWP (~1). No near-term sunset dates. Widely promoted as a sustainable replacement for R-245fa.R-123 (HCFC, historical use)Temperature at 300 psi (20.7 bar): ~110 °C (230 °F)Carnot Efficiency (vs 30 °C / 86 °F condenser): ~23 percentCondenser Temperature: Best around 25–30 °C (77–86 °F)Notes: Phased out globally under the Montreal Protocol due to ozone depletion potential. Not viable for new ORC systems.R-600 (n-Butane)Temperature at 300 psi (20.7 bar): ~140 °C (284 °F)Carnot Efficiency (vs 30 °C / 86 °F condenser): ~27 percentCondenser Temperature: Optimal near 25–30 °C (77–86 °F)Notes: Low GWP but highly flammable. Regulatory and safety concerns limit adoption in many regions.R-601 (Pentane)Temperature at 300 psi (20.7 bar): ~160 °C (320 °F)Carnot Efficiency (vs 30 °C / 86 °F condenser): ~30 percentCondenser Temperature: Performs best at 25–30 °C (77–86 °F)Notes: Low GWP hydrocarbon with strong thermodynamic performance, but flammability is a concern.R-152aTemperature at 300 psi (20.7 bar): ~100 °C (212 °F)Carnot Efficiency (vs 30 °C / 86 °F condenser): ~21 percentCondenser Temperature: 25–30 °C (77–86 °F)Notes: Moderate GWP (~124). Being phased down under F-Gas rules, but sometimes used as a substitute for higher-GWP fluids.Summary Table at 300 psi| Refrigerant | Temp at 300 psi (°C / °F) | Carnot Efficiency (%) | Best Condenser Temp (°C / °F) | Notes || --• | • | --• | -• | -• || R-245fa | 125 / 257 | 25 | 30–35 / 86–95 | High GWP, EU sunset || R-1233zd(E) | 155 / 311 | 29 | 25–35 / 77–95 | Low GWP HFO, no sunset || R-123 | 110 / 230 | 23 | 25–30 / 77–86 | HCFC, phased out || R-600 (Butane) | 140 / 284 | 27 | 25–30 / 77–86 | Low GWP, flammable || R-601 (Pentane) | 160 / 320 | 30 | 25–30 / 77–86 | Low GWP, flammable || R-152a | 100 / 212 | 21 | 25–30 / 77–86 | Moderate GWP, phasedown |ConclusionWhen standardized at 300 psi, ORC refrigerants show clear performance distinctions. Hydrofluoro-olefins like R-1233zd(E) provide both high thermal capability and regulatory acceptance. Hydrocarbons such as pentane and butane offer solid performance but pose flammability risks. Legacy fluids like R-123 and high-GWP HFCs like R-245fa are being phased out. Choosing the right refrigerant depends on balancing efficiency, condenser conditions, and regulatory compliance for the ORC application.
Note: Infinity systems are not designed for flammable working fluids
INFINITY TURBINE LLC We specialize in designs, plans, licensing, consulting, design services, and surplus spare parts. We no longer manufacture turbines or CO2 systems. More Info...
Please email for first contact with request for more information
Email: greg@infinityturbine.com
Infinity Turbine CO2 Turbine Development and Testing Cart Supercritical CO2 Turbine Development Cart using high pressure filter canisters for rapid prototyping and commercialization for 1-25 kWh Power Generation... More Info
ORC and sCO2 Performance Charts: R134a, R245fa, CO2 – 2026 Edition Updated 2026 edition of Infinity Turbine’s ORC and supercritical CO2 performance curves: R134a, R245fa and CO2 charts, CO2 heat-rate tables from 100 to 700 °C, sCO2 turbine types, and data-center applications. 62-page PDF... More Info
Supercritical CO2 Turbine Generator Plans (Transcritical) Rankine Cycle Lab format for development ... More Info
Matra Concentrated Solar Project Using Infinity Turbine Generator for Power Production Solar thermal power production using a reflective dish concentrator... More Info
Cluster Mesh Supercritical CO2 Power System for Data Centers and AI Pairing Cluster Mesh Supercritical CO2 Power System with Small Modular Reactors enables hyperscalers to convert high-grade nuclear heat into ultra-efficient, dispatchable power with a compact, modular footprint tailored for AI-scale demand. More Info
ORC and Products Index Infinity Turbine ORC Index... More Info
A Generator Without Magnets Switched Reluctance is the simplest rotating electrical machine there is: a rotor of stacked steel laminations with salient teeth, and a stator carrying concentrated coils. The rotor has no magnets, no windings, no bars and no slip rings... More Info
CONTACT Email: greg@infinityturbine.com
(Standard Web Page) | PDF