Pulsed Heat Pump Data Center Cooling by Infinity Turbine
Revolutionizing Data Center Cooling: Using Supercritical CO2 for Efficient Cooling of Nvidia A100 GPUs
As data centers grow in size and computing power, efficient cooling systems are becoming more critical than ever. High-performance GPUs, like the Nvidia A100, generate significant amounts of waste heat, creating the need for more advanced thermal management systems. Traditional cooling methods such as air and water cooling are becoming less efficient as server densities increase.A new concept leveraging supercritical CO2 (sCO2) for cooling Nvidia A100 GPUs offers an innovative solution by harnessing the waste heat from the GPUs and providing substantial cooling through pressure drop expansion. This article explores the potential benefits of this technology, the calculations behind it, and how it can result in significant energy savings for data centers, particularly those with high-performance workloads.
The Problem with Traditional Cooling Systems
In conventional air-cooled data centers, large fans and air conditioning units are required to keep GPUs at safe operating temperatures. This method, while simple, becomes inefficient as the number of servers increases. Similarly, water cooling systems, though more efficient than air cooling, involve complex plumbing and maintenance issues and require substantial amounts of energy to pump water through the system. As data centers scale up, these cooling systems become increasingly expensive to operate and maintain.A typical Nvidia A100 GPU consumes 300 watts (W) of power, and most of this energy is converted into heat that must be managed effectively to prevent overheating and ensure stable performance. In a data center with 50,000 Nvidia A100 GPUs, this generates 15 megawatts (MW) of waste heat that needs to be dissipated.Harnessing Waste Heat with Supercritical CO2 CoolingThe supercritical CO2 cooling concept offers a more efficient way to manage this heat by capturing it and utilizing it for further cooling. CO2 is heated to its supercritical state (above 31°C and 73.8 bar) where it behaves like both a gas and a liquid, making it highly efficient at transferring heat.Here’s a breakdown of how the system works:1. Liquid CO2 enters a heat exchanger where it absorbs the waste heat from the Nvidia A100 GPUs.2. As it heats up, the CO2 transitions into its supercritical phase, where it can absorb even more heat.3. The CO2 is then passed through an ejector pump, creating a pressure drop that rapidly cools the GPUs. This cooling effect takes advantage of the Joule-Thomson effect, where expanding CO2 experiences a significant temperature drop.The efficiency of this process can be illustrated with the following calculations.Calculating the Waste Heat and Cooling EfficiencyEach Nvidia A100 GPU generates about 300 watts of heat, and we’ve already calculated that:• Total power consumption for 50000 GPUs:50000 GPUs times 300 W = 15000000 W (15 MW)This equates to 15 megawatts of waste heat generated by the GPUs.• Waste heat per GPU in BTUhour:300 W times 3.412 BTUhour per W = 1023.6 BTUhourFor 50000 GPUs the total waste heat is:1023.6 BTU/hour per GPU x 50000 GPUs = 51,180,000 BTU/hourThis is the amount of heat that needs to be managed.Cooling with CO2 Expansion• Initial conditions: The CO2 is heated to 60°C (140°F) in the supercritical state, with a pressure of around 80 bar.• Expansion: The CO2 is expanded to 10 bar using an ejector pump, which results in a pressure drop and significant cooling.The cooling effect is calculated based on the change in enthalpy:• Before expansion: At 60°C and 80 bar, the enthalpy is approximately 420 kJ/kg.• After expansion: At 10 bar, the enthalpy drops to around 230 kJ/kg.This gives a cooling effect of: 190 kJkgThis cooling effect significantly reduces the temperature of the supercritical CO2, with the final temperature dropping to around -10°C to -20°C (14°F to -4°F). This cooling can then be distributed across the GPUs, providing efficient heat dissipation.Energy Savings from Supercritical CO2 CoolingOne of the key advantages of the supercritical CO2 system is its ability to reduce the energy required for cooling compared to traditional air and water cooling systems. Let’s examine the potential savings:1. Fan Energy Savings:In air-cooled systems, large fans are needed to cool down GPUs. For a data center of this size, the energy consumption of fans can be substantial. Cooling infrastructure typically consumes up to 30-50% of the total energy used in a data center. In our case, for a 15 MW data center, the cooling energy could be as high as 7.5 MW.By using supercritical CO2 cooling, much of this energy could be saved. Even a 50% reduction in cooling energy would save around 3.75 MW of power.2. Water Cooling System Savings:Water cooling systems require pumps to circulate liquid, heat exchangers, and sometimes chillers. These systems are more energy-efficient than air cooling but still require significant power to operate.By replacing water cooling with supercritical CO2, the energy consumption related to pumping and cooling water could be eliminated. This would reduce the complexity of the infrastructure and result in energy savings.3. Maintenance and Operational Savings:The One-way valve design for controlling fluid flow in this system has no moving parts, making it a maintenance-free solution compared to mechanical valves and pumps in water cooling systems. Over time, this reduces operational costs and increases system reliability.Total Potential SavingsFor a data center with 50,000 Nvidia A100 GPUs:• Cooling system savings:If the supercritical CO2 system reduces cooling power consumption by even 3.75 MW, this translates to significant cost savings in terms of energy. Assuming an energy cost of $0.10 per kWh, the annual savings would be:3.75 MW x 24 hours/day x 365 days/year x 0.10 $/kWh = $3.3 million dollars/yearIn addition to these direct energy savings, the improved cooling efficiency could enable the data center to run more GPUs at full capacity, further optimizing performance and reducing hardware stress from overheating.Conclusion: The Future of Data Center Cooling with CO2The adoption of supercritical CO2 cooling with One-way valves in data centers represents a leap forward in thermal management for high-performance computing environments. With the ability to capture and utilize waste heat from Nvidia A100 GPUs, this system not only provides more efficient cooling but also results in significant energy savings compared to traditional air and water cooling systems.For large-scale data centers with tens of thousands of GPUs, such as those used for AI and machine learning workloads, the transition to CO2-based cooling could reduce operational costs by millions of dollars annually, while also decreasing environmental impact through reduced energy consumption. As data centers continue to scale, the demand for innovative cooling technologies like this will become essential for maintaining performance, efficiency, and sustainability.
Maintaining Efficiency in Data Center Cooling: How the Ejector Pump Prevents Equilibrium in the Pulsed Supercritical Heat Pump
In the rapidly evolving world of data centers, cooling high-performance GPUs like the Nvidia A100 is a critical challenge. As computational power grows, so does the need for more efficient, reliable cooling systems that can handle the intense heat generated by these powerful chips. Enter the Pulsed Supercritical Heat Pump, an innovative cooling technology that uses supercritical CO2 to manage waste heat in data centers more effectively.
How the Ejector Pump Prevents Equilibrium in the Pulsed Supercritical Heat Pump
One of the most important components of this system is the ejector pump, which ensures the cooling process remains efficient and continuous. Without this vital element, the system could potentially reach equilibrium, where temperature and pressure balance out, reducing its ability to dissipate heat effectively. This article explores how the ejector pump plays a critical role in preventing equilibrium in the Pulsed Supercritical Heat Pump, ensuring the system operates at peak efficiency.What Is the Pulsed Supercritical Heat Pump?The Pulsed Supercritical Heat Pump is a revolutionary cooling system designed to handle the extreme heat generated by modern data centers, particularly those using GPUs like the Nvidia A100. The system works by cycling supercritical CO2 through a series of heat exchangers, where it absorbs heat from the GPUs and provides significant cooling through pressure drop expansion.The system relies on supercritical CO2, which has both gas and liquid properties, making it an extremely efficient medium for heat transfer. When CO2 is heated above its critical temperature of 31°C (87.9°F) and critical pressure of 73.8 bar, it enters a supercritical state. In this state, CO2 can absorb large amounts of heat, making it ideal for cooling data center GPUs.Why Equilibrium Is a Potential ChallengeIn a cascading cooling system, like the one used in the Pulsed Supercritical Heat Pump, there is always the risk of the system reaching equilibrium. Equilibrium, in this context, means that the temperature and pressure gradients driving the heat transfer and cooling process could equalize over time, causing the system to lose efficiency. If the system reaches equilibrium, the CO2 will no longer be able to absorb and transfer heat effectively, reducing the system’s overall cooling capability.The Role of the Ejector Pump in Preventing EquilibriumTo prevent equilibrium and ensure continuous, effective cooling, the Pulsed Supercritical Heat Pump relies on an ejector pump. The ejector pump is a critical component because it maintains the necessary pressure drops that drive the cooling process.Here’s how the ejector pump works to prevent equilibrium:1. Maintaining Pressure DropsThe ejector pump creates a pressure differential by forcing the supercritical CO2 through a nozzle, creating a low-pressure zone that ensures the CO2 expands rapidly. This pressure drop is key to generating the Joule-Thomson effect, where the temperature of the CO2 decreases significantly as it expands. This cooling effect is critical for the heat exchange process, preventing the system from reaching a balanced, inefficient state.By maintaining consistent pressure drops, the ejector pump ensures that the CO2 continues to cycle through the system effectively, providing continuous cooling for the GPUs.2. Driving Fluid CirculationIn a closed-loop cooling system, the ejector pump plays a vital role in keeping the CO2 circulating through the system. The pump draws CO2 from the high-pressure side of the system, expands it to a lower pressure, and drives the cooled fluid into the next heat exchanger. This continuous movement of fluid ensures that the system does not settle into a static state, where pressure and temperature would equalize and prevent effective cooling.The pulsing action of the ejector pump creates a consistent flow of CO2, allowing the cooling process to continue without interruption. This is particularly important in a cascade system, where multiple stages of cooling rely on each stage having a sufficient pressure and temperature difference to transfer heat effectively.3. Dynamic Control Without Moving PartsUnlike traditional pumps or compressors, the ejector pump in this system has no moving parts. It operates passively by using the energy already present in the flowing CO2. This makes the system highly reliable and low maintenance, while still providing the dynamic control needed to prevent equilibrium.The lack of moving parts also means the ejector pump can operate continuously without the wear and tear associated with mechanical pumps, ensuring long-term reliability in high-performance data center environments.Avoiding System Equilibrium in a Closed LoopIn a closed-loop cooling system like the Pulsed Supercritical Heat Pump, preventing equilibrium is crucial to maintaining cooling efficiency. The system relies on consistent pressure and temperature differentials to transfer heat away from the GPUs and dissipate it effectively.The ejector pump is essential for:• Preventing pressure equalization: By creating consistent pressure drops, the ejector pump ensures that each stage of the cooling process has a sufficient pressure differential to continue transferring heat.• Driving fluid movement: Without the ejector pump, the system could become static, leading to reduced heat transfer and cooling efficiency.• Ensuring dynamic cooling: The system remains dynamic, with the cooling fluid constantly in motion, preventing it from reaching a stable, inefficient state.How the Ejector Pump Keeps the Cooling System in BalanceWhile the system does not reach equilibrium, the ejector pump keeps the Pulsed Supercritical Heat Pump in a state of dynamic equilibrium. This means that while the system maintains balance in terms of energy transfer, it avoids the stagnation associated with true equilibrium, where temperature and pressure differences would neutralize each other.By continually managing the flow and pressure of the CO2, the ejector pump ensures that the system remains in constant motion, allowing it to efficiently dissipate heat and maintain optimal cooling performance for high-performance GPUs like the Nvidia A100.Conclusion: The Key to Efficient, Continuous CoolingThe Pulsed Supercritical Heat Pump represents a significant advancement in cooling technology for data centers, and the ejector pump is the cornerstone of its success. By preventing equilibrium and maintaining the necessary pressure drops and fluid circulation, the ejector pump ensures that the cooling system operates efficiently and continuously, without the need for moving parts or complex mechanical systems.For data centers running thousands of Nvidia A100 GPUs, this technology promises not only reduced energy consumption and maintenance costs, but also enhanced reliability and performance. With its ability to prevent equilibrium and maintain dynamic cooling, the Pulsed Supercritical Heat Pump offers a solution for the future of data center thermal management, where efficiency, reliability, and scalability are paramount.For more information on the Pulsed Supercritical Heat Pump and how it can revolutionize your data center cooling, visit Infinity Turbine and learn how this innovative technology can help you achieve optimal performance and sustainable cooling.
Nvidia A100 Chip Waste Heat
The Nvidia A100 chip, a high-performance GPU widely used in data centers for AI workloads, generates a significant amount of waste heat during operation. To estimate the recoverable waste heat from an Nvidia A100 chip, we need to consider the chip's power consumption and its thermal efficiency.
Key Factors to Consider
1. Power Consumption:• The power consumption of the Nvidia A100 chip depends on the specific model and usage scenario. However, the A100 can draw around 300 watts (W) or more under full load.2. Heat Dissipation:• The A100 chip, like all electronic components, converts most of the electrical power it consumes into heat. Typically, the power consumed by a GPU is converted into waste heat that needs to be dissipated to maintain safe operating temperatures.Recoverable Waste Heat EstimateAssuming that nearly all of the electrical power is converted into heat (as is common with GPUs), the waste heat generated by a single Nvidia A100 GPU can be estimated as follows:• Power Consumption: 300 W• Heat Dissipation: 300 WConversion to BTU/hourTo express the waste heat in BTU per hour (BTU/h), we can use the conversion factor:1 Watt = 3.412 BTUhourFor the Nvidia A100 chip:300 W x 3.412 BTU/hour per W = 1,023.6 BTU/hourTherefore, the recoverable waste heat from an Nvidia A100 GPU chip is approximately 1,024 BTU per hour.Considerations for Heat Recovery• Cooling Method: The recoverable heat depends on the cooling system used. A water-cooled or CO2-based system (such as the supercritical CO2 concept discussed earlier) could capture a large portion of this waste heat efficiently.• Energy Recovery Efficiency: Not all waste heat may be recoverable for reuse. The efficiency of the heat recovery system (e.g., a heat exchanger or waste heat recovery unit) will determine how much of the 1,024 BTU/hour can be used for power generation or other purposes.In ideal conditions, a well-designed heat recovery system could capture most of this heat, especially in liquid cooling or CO2 cooling systems where the heat is transferred directly from the chips to the working fluid.ConclusionThe Nvidia A100 chip generates approximately 1,024 BTU/hour of waste heat under full load, which can be recovered using advanced cooling and heat recovery technologies. The amount of heat recovered will depend on the efficiency of the cooling system and the design of the heat recovery infrastructure in the data center.
The temperature of the waste heat from an Nvidia A100 chip
The temperature of the waste heat from an Nvidia A100 chip depends on several factors, including the thermal characteristics of the chip, the cooling system used, and how efficiently heat is dissipated. However, we can estimate the temperature of the waste heat based on typical operating conditions for high-performance GPUs like the A100.
Nvidia A100 Chip Temperature
Operating Temperature of the A100 ChipThe Nvidia A100 chip is designed to operate at safe temperatures under load. Based on general specifications for high-performance GPUs, the following temperatures are typical:• Typical Operating Temperature: Under full load, the A100 may operate at temperatures ranging from 70°C to 85°C (158°F to 185°F).• Thermal Throttling Limit: Most high-performance GPUs, including the A100, are designed to throttle their performance if temperatures exceed 85°C to 90°C (185°F to 194°F) to prevent damage.Temperature of Waste HeatThe actual temperature of the waste heat will depend on how the cooling system transfers heat away from the chip. However, we can assume the following general estimates based on typical cooling systems:1. Air Cooling:• In air-cooled systems, the waste heat will be transferred to the surrounding air via heat sinks and fans. The exhaust temperature of the air from these systems typically ranges from 40°C to 60°C (104°F to 140°F).2. Liquid Cooling:• In liquid-cooled systems, the heat is transferred more efficiently to the cooling liquid, resulting in cooler exhaust temperatures compared to air cooling. The liquid temperature entering the cooling loop might be around 30°C to 40°C (86°F to 104°F), and after absorbing heat from the chip, it could reach 45°C to 60°C (113°F to 140°F) before being cooled again.3. CO2 Cooling (Supercritical CO2):• If the supercritical CO2 cooling system is used, the working fluid (CO2) can absorb large amounts of heat while maintaining a relatively low temperature. The CO2 temperature at the chip interface might range from 45°C to 70°C (113°F to 158°F), depending on the system's efficiency and the phase of the CO2.Factors Affecting Waste Heat Temperature• Cooling Efficiency: More efficient cooling systems (e.g., liquid or supercritical CO2) will result in lower waste heat temperatures at the exhaust, as they are able to capture and transfer heat more effectively.• Workload: Under heavy loads, the GPU will produce more waste heat, potentially leading to higher exhaust temperatures.• System Design: The design of the cooling loop, including heat exchangers and radiators, will determine the final temperature of the waste heat as it is expelled from the system.Conclusion• The operating temperature of the Nvidia A100 chip ranges from 70°C to 85°C (158°F to 185°F).• The temperature of the waste heat will vary depending on the cooling method, but it can be expected to range from 40°C to 60°C (104°F to 140°F) in air-cooled systems, and 45°C to 70°C (113°F to 158°F) in liquid or supercritical CO2 cooling systems.These temperatures provide an estimate of the heat that can be recovered and managed through advanced cooling systems in a data center.
CO2 Supercritical Temperature and Pressure Drop for NVIDA A100 GPU Chipset
To calculate the resulting pressure when waste heat is transferred into CO2 and how it behaves during expansion, we need to use the properties of CO2 in both its liquid and supercritical states. We can also estimate the cooling effect when the CO2 expands and the final pressure and temperature after expansion.
Temperature and Pressure Drop
Step 1: Initial Conditions of CO2Let’s assume the CO2 starts as a liquid or subcooled liquid and is heated to a supercritical state by the waste heat from the Nvidia A100 chip.• Waste heat: Approximately 1,024 BTU/hour (as calculated earlier).• Temperature of the waste heat: Let’s assume an initial cooling system temperature around 40°C to 60°C (104°F to 140°F), in line with typical operating temperatures in air• or liquid-cooled systems.In a CO2 cooling system, we are particularly interested in its behavior around the critical point of CO2:• Critical Temperature (Tc): 31.1°C (87.9°F)• Critical Pressure (Pc): 73.8 bar (7.38 MPa or 1,070 psi)At temperatures above 31.1°C and pressures above 73.8 bar, CO2 enters the supercritical phase where it has properties of both a liquid and a gas, making it an excellent heat transfer medium.Step 2: Heating CO2 to Supercritical ConditionsLet’s assume we are heating liquid CO2 from an initial condition of 25°C (77°F) up to a supercritical state of 60°C (140°F). At this temperature:• At 25°C and 5.6 MPa (56 bar), CO2 is still in its liquid state.• As we apply waste heat, CO2 heats up and enters its supercritical phase at temperatures above 31.1°C and pressures above 73.8 bar.Let’s assume the waste heat raises the temperature of the CO2 to 60°C (140°F). In this supercritical state, at 60°C, the pressure would typically be in the range of 80 bar to 100 bar.Step 3: Expansion of CO2 and Resulting PressureWhen CO2 in the supercritical phase undergoes adiabatic expansion (meaning no heat is exchanged with the surroundings during expansion), the pressure drops, and the gas cools down significantly due to the Joule-Thomson effect.The pressure after expansion depends on how much the volume is allowed to increase. If CO2 expands through a turbine or ejector in the cooling system, the pressure drop can be significant, and the resulting cooling can be used for further thermal management.Let’s assume the CO2 expands from 80 bar to a lower pressure of 10 bar (1 MPa or 145 psi). At this pressure, CO2 undergoes significant cooling.Step 4: Cooling Effect and Final TemperatureThe cooling effect can be approximated using enthalpy drop during the expansion. Using thermodynamic tables for CO2, we can estimate the final temperature and cooling effect:• Before expansion: At 60°C and 80 bar, the enthalpy of supercritical CO2 is around 420 kJ/kg.• After expansion: At 10 bar, the enthalpy drops to around 230 kJ/kg.The difference in enthalpy gives us the cooling effect:Delta h = 420 kJkg - 230 kJkg = 190 kJkgThis represents the amount of cooling provided by the expanding CO2.The final temperature of the CO2 after expansion will also drop significantly due to the expansion:• At 10 bar, CO2 can cool to temperatures as low as -10°C to -20°C (14°F to -4°F), depending on the specific expansion process.Step 5: Summary of Results1. Initial Pressure and Temperature: CO2 is heated to 60°C in the supercritical phase, with a pressure around 80 bar.2. Expansion: The CO2 is expanded to 10 bar, causing a significant pressure drop.3. Cooling and Final Temperature: The cooling effect due to expansion results in a temperature drop to approximately -10°C to -20°C (14°F to -4°F). The system experiences a cooling effect of 190 kJ/kg.ConclusionBy utilizing the waste heat from an Nvidia A100 chip, CO2 can be heated to a supercritical state. When expanded through an ejector or turbine, this results in a significant pressure drop and cooling effect, with temperatures dropping to around -10°C to -20°C depending on the expansion. This cooling can be highly effective for further heat management in a data center environment, providing a highly efficient method to recover and reuse waste heat for GPU cooling.
TEL: 1-608-238-6001 Email: greg@infinityturbine.com
Salgenx Grid-Scale Battery 3000 kWh MegaWatt Pack | License and Build $600,000 for 3000 kWh battery using salt in a flow battery system... More Info
License and Build the Salgenx MegaWatt Pack and Realize $300,000 income and $105,000 Per Battery With a license, you will have access $1.2 Billion in pre orders. Consider that Tesla MegaPack has a one year waitlist and around 10,400 orders in queue (the market is huge)... More Info
The Company That Controls Battery Technology Controls the World A Look at the New Contenders from Tesla to Salgenx Saltwater MegaWatt Pack... More Info
Data Center Energy Strategies Using Cluster Mesh Power Generation Learn more about cooling and power strategies for Data Centers for the Cloud and AI... More Info
ORC Radial Outflow Turbine Flat Pack Kit Infinity Turbine is now offering a ROT Radial Outflow Turbine for customer assembly flat pack kit.... More Info
Sodium Flow Grid-Scale Battery Technology Report With insights derived from extensive research and engineering expertise, the report offers valuable recommendations for optimizing financial viability, includes how to build demo... More Info
Pulse Cooling for Data Center GPUs Efficiently cool data center GPUs using supercritical CO2 technology for unmatched energy savings and performance... More Info
NVIDIA Blackwell Heating Issues Discover how Infinity Turbine's Pulsed Heat Pump Cooling Technology tackles the overheating challenges of Nvidia's Blackwell chips... More Info